WWW.JNEUROSCI.ORG
-
The Journal of Neuroscience
 QUICK SEARCH:   [advanced]


     
-


HOME
  |  
SEARCH  |   ARCHIVE  |   SUBSCRIBE  |   CONTACT  |   HELP

The Journal of Neuroscience, March 24, 2004, 24(12):2914-2922; doi:10.1523/JNEUROSCI.5346-03.2004

This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Submit an eLetter
Right arrow Alert me when this article is cited
Right arrow Alert me when eLetters are posted
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow reprints & permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Web of Science (14)
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Dhingra, N. K.
Right arrow Articles by Smith, R. G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Dhingra, N. K.
Right arrow Articles by Smith, R. G.

 Previous Article  |  Next Article 

Behavioral/Systems/Cognitive
Spike Generator Limits Efficiency of Information Transfer in a Retinal Ganglion Cell

Narender K. Dhingra and Robert G. Smith

Department of Neuroscience, University of Pennsylvania, Philadelphia, Pennsylvania 19104-6058

The quality of the signal a retinal ganglion cell transmits to the brain is important for preception because it sets the minimum detectable stimulus. The ganglion cell converts graded potentials into a spike train with a selective filter but in the process adds noise. To explore how efficiently information is transferred to spikes, we measured contrast detection threshold and increment threshold from graded potential and spike responses of brisk-transient ganglion cells. Intracellular responses to a spot flashed over the receptive field center of the cell were recorded in an intact mammalian retina maintained in vitro at 37°C. Thresholds were measured in a single-interval forced-choice procedure with an ideal observer. The graded potential gave a detection threshold of 1.5% contrast, whereas spikes gave 3.8%. The graded potential also gave increment thresholds approximately twofold lower and carried ~60% more gray levels. Increment threshold "dipped" below the detection threshold at a low contrast (<5%) but increased rapidly at higher contrasts. The magnitude of the "dipper" for both graded potential and spikes could be predicted from a threshold nonlinearity in the responses. Depolarization of the cell by current injection reduced the detection threshold for spikes but also reduced the range of contrasts they can transmit. This suggests that contrast sensitivity and dynamic range are related in an essential trade-off.

Key words: retina; discrimination; contrast; threshold; spike; information


Received Dec 3, 2003; revised February 6, 2004; accepted February 9, 2004.




This article has been cited by other articles:


Home page
J. Physiol.Home page
V. Balasubramanian and P. Sterling
Receptive fields and functional architecture in the retina
J. Physiol., June 15, 2009; 587(12): 2753 - 2767.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
B. G. Borghuis, P. Sterling, and R. G. Smith
Loss of Sensitivity in an Analog Neural Circuit
J. Neurosci., March 11, 2009; 29(10): 3045 - 3058.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
B. G. Borghuis, C. P. Ratliff, R. G. Smith, P. Sterling, and V. Balasubramanian
Design of a Neuronal Array
J. Neurosci., March 19, 2008; 28(12): 3178 - 3189.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
M. Greschner, A. Thiel, J. Kretzberg, and J. Ammermuller
Complex Spike-Event Pattern of Transient ON-OFF Retinal Ganglion Cells
J Neurophysiol, December 1, 2006; 96(6): 2845 - 2856.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
N. K. Dhingra, M. A. Freed, and R. G. Smith
Voltage-Gated Sodium Channels Improve Contrast Sensitivity of a Retinal Ganglion Cell
J. Neurosci., August 31, 2005; 25(35): 8097 - 8103.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
E. S. Frechette, A. Sher, M. I. Grivich, D. Petrusca, A. M. Litke, and E. J. Chichilnisky
Fidelity of the Ensemble Code for Visual Motion in Primate Retina
J Neurophysiol, July 1, 2005; 94(1): 119 - 135.
[Abstract] [Full Text] [PDF]


Home page
J. Neurophysiol.Home page
Y. Xu, N. K. Dhingra, R. G. Smith, and P. Sterling
Sluggish and Brisk Ganglion Cells Detect Contrast With Similar Sensitivity
J Neurophysiol, May 1, 2005; 93(5): 2388 - 2395.
[Abstract] [Full Text] [PDF]


Home page
J. Neurosci.Home page
E. J. Chichilnisky and F. Rieke
Detection Sensitivity and Temporal Resolution of Visual Signals near Absolute Threshold in the Salamander Retina
J. Neurosci., January 12, 2005; 25(2): 318 - 330.
[Abstract] [Full Text] [PDF]



-
-

Home  |   Search  |   Archive  |   Subscribe  |   Contact  |   Help

-
Copyright 2009 by Society for Neuroscience ONLINE ISSN: 1529-2401
-