Previous Article | Next Article 
The Journal of Neuroscience, June 15, 2001, 21(12):4460-4468
Capsaicin Responses in Heat-Sensitive and Heat-Insensitive
A-Fiber Nociceptors
Matthias
Ringkamp1,
Yuan B.
Peng1,
Gang
Wu1,
Timothy V.
Hartke1,
James N.
Campbell1, 2, and
Richard A.
Meyer1, 2
1 Department of Neurosurgery, School of Medicine, Johns
Hopkins University, Baltimore, Maryland 21287, and 2 Johns
Hopkins Applied Physics Laboratory, Laurel, Maryland 20723
 |
ABSTRACT |
The recently cloned vanilloid receptor (VR1) is postulated to
account for heat and capsaicin sensitivity in unmyelinated afferents. We sought to determine whether heat and capsaicin sensitivity also coexist in myelinated nociceptive afferents. Action potential (AP) activity was recorded from single A-fiber nociceptors that innervated the hairy skin in monkey. Before intradermal injection of
capsaicin (10 µg/10 µl) into the receptive field, nociceptors were
classified as heat-sensitive (threshold,
53°C, 1 sec) or heat-insensitive afferents and as mechanically sensitive (von Frey
threshold, <6 bar) or mechanically insensitive afferents. All
heat-sensitive afferents (n = 16) were insensitive
to mechanical stimuli but responded to the intradermal injection of
capsaicin (69 ± 7 APs in 10 min). Responsiveness to mechanical
stimuli, thermal stimuli, and capsaicin varied in their receptive
fields; the majority of receptive field sites (24 of 36) were
responsive to only one or two stimulus modalities, whereas only eight
sites responded to all three modalities. For most heat-insensitive
afferents, the activity induced by the capsaicin injection did not
exceed the activity induced by needle insertion alone. However, the
largest response to capsaicin (314 ± 98 APs in 10 min) was
observed for five afferents that were insensitive to heat as well as
mechanical stimuli and therefore may be classified as cutaneous
chemoreceptors. These results suggest that A-fiber nociceptors play a
role in the pain and hyperalgesia associated with capsaicin injection. Our finding that a subgroup of capsaicin-sensitive A-fiber nociceptors are insensitive to heat predicts the existence of heat-insensitive capsaicin receptors.
Key words:
capsaicin; myelinated nociceptors; heat sensitivity; primate; monkey; hairy skin; receptive field; mechanically insensitive
afferents
 |
INTRODUCTION |
Intradermal injection of capsaicin
in humans produces intense pain and secondary hyperalgesia. Intradermal
injection of capsaicin weakly activates conventional C-fiber
nociceptors (Baumann et al., 1991
) but produces a vigorous response in
a subtype of C-fiber nociceptors that are insensitive to mechanical
stimuli (Schmelz et al., 2000
). However, little is known about the
responses of A-fiber nociceptors to capsaicin, and therefore the role
of A-fiber nociceptors in capsaicin-evoked pain and hyperalgesia is unknown.
A-fiber nociceptive afferents in primate have been classified into
three types based on their responsiveness to heat stimuli (Treede et
al., 1995
, 1998
). Type I afferents are relatively insensitive to heat
stimuli but respond with a long latency to intense, long-duration heat
stimuli (e.g., 53°C, 30 sec). Type II afferents are sensitive to heat
(threshold ~47°C, 1 sec) and respond briskly (latency,
200 msec)
to intense heat. High-threshold mechanoreceptive nociceptors (HTMs) are
unresponsive to heat stimuli. The relative response of these different
classes of A-fiber nociceptors to capsaicin is unknown.
For unmyelinated nociceptors, heat and capsaicin sensitivity are
thought to coexist and to be encoded, at least in part, by the recently
cloned vanilloid receptor 1 (VR1) (Caterina et al., 1997
). It
appears that heat and capsaicin sensitivity may also coexist in some
A-fiber nociceptors. First pain to heat is mediated by type II A-fiber
nociceptors (Campbell and LaMotte, 1983
). Because first pain to heat is
lost after topical application of capsaicin, type II A-fiber
nociceptors must have capsaicin sensitivity. However, the VR1 receptor
is not found in myelinated afferents. Thus, a similar receptor likely
accounts for heat sensitivity in type II A-fiber nociceptors.
The recently cloned vanilloid receptor-like protein (VRL1)
receptor has a high heat threshold and is found in large dorsal root
ganglia neurons. The VRL1 receptor is proposed to be responsible for heat transduction of type I A-fiber nociceptors (Caterina et al.,
1999
). Because the VRL1 receptor does not respond to capsaicin, type I
A-fiber nociceptors are thought to be insensitive to capsaicin.
To elucidate further the relationship between heat and capsaicin
sensitivity in nociceptive neurons and to assess the potential role of
A-fiber nociceptors in capsaicin-evoked pain, we investigated in the
present study the capsaicin responses of A-fiber nociceptive afferents.
Because type I heat-insensitive and type II heat-sensitive A-fiber
nociceptors have been found in nonhuman primates, studies were
conducted in monkeys.
 |
MATERIALS AND METHODS |
General procedures. Monkeys (Macaca
fascicularis and Macaca mulatta) were initially sedated
with ketamine (10 mg/kg) followed by an intravenous bolus injection of
pentobarbital (7 mg/kg) to achieve anesthesia. A continuous intravenous
infusion of pentobarbital (3-6
mg · kg
1 · hr
1)
or, alternatively, a mixture of pentobarbital (3 mg · kg
1 · hr
1)
and morphine sulfate (0.5 mg · kg
1 · hr
1)
was started. Animals were hydrated with a continuous infusion of 5%
dextrose in physiological saline solution (4-6
mg · kg
1 · hr
1).
To prevent bacterial infection, a prophylactic intramuscular injection
of penicillin G was given (300,000 U). Heart rate was continuously
monitored by an electrocardiogram and used as an indicator of adequate
anesthesia. Heart rate was kept within 10% of the initial baseline
rate before any manipulations. Upon an increase in heart rate during or
after a noxious intervention, a bolus of anesthetic was given to secure
an adequate level of anesthesia. Muscle relaxation was induced by an
intravenous dose of pancuronium bromide (0.1 mg/kg) and maintained by
supplemental doses every 2-3 hr. Animals were intubated and ventilated
with expired pCO2 adjusted to 40 mmHg. Animal
core temperature was measured by a rectal probe and maintained at
38°C using feedback-controlled, water-perfused heating pads. All
procedures were approved by the Johns Hopkins Animal Care and Use Committee.
Recordings were made from nerves innervating hairy skin, including the
saphenous (n = 14), superficial peroneal
(n = 6), sural (n = 2), superficial
radial (n = 17), and medial antebrachial cutaneous
nerves (n = 6). Teased-fiber recording techniques were used as described in detail previously (Campbell and Meyer, 1983
). Briefly, the cutaneous nerve of interest was isolated from the surrounding connective tissue under a dissecting microscope. The skin
around the incision was used to form a pool by suturing the edges to a
metal ring. The pool was filled with paraffin oil. A splitting
platform, which also served as the ground electrode, was placed
underneath the nerve, and a small silver wire, which served as the
recording electrode, was positioned above the splitting platform. Small
bundles were cut from the nerve, and their distal stumps were teased
into small filaments from which single fibers could be recorded.
Signals were differentially amplified, filtered, and displayed on an
oscilloscope (see also data collection). Between the splitting platform
and the distal edge of the pool, a tripolar electrode was positioned on
the nerve with the outer electrodes serving as anodes. This distal
stimulation electrode was used to deliver electrical pulses of variable
strength to the nerve to identify the fibers on the recording electrode
and to determine their conduction latency. To calculate the conduction
velocity, the conduction length between the recording electrode and the nerve stimulation electrode (typically 3-4 cm) was measured and divided by the conduction latency obtained at an intensity three times
above threshold for excitation. Fibers with a conduction velocity >2
m/sec as determined from the nerve stimulation electrode were regarded
as A-fibers (Treede et al., 1998
).
Mapping the receptive field. The cutaneous receptive field
of the afferent under study was localized by gently squeezing the skin
in the innervation territory of the respective nerve. The mechanoreceptive field was mapped using a von Frey hair. For
mechanically sensitive afferents (MSAs), an 8.6 bar von Frey hair was
used, whereas for mechanically insensitive afferents (MIAs) (von
Frey threshold, >6 bar) (Meyer et al., 1991
), a 15 bar von Frey hair was used. Mechanically sensitive spots were marked on the skin with
colored ink. After mapping, the mechanical threshold of the afferent
fiber was determined by applying a series of von Frey hairs of
increasing strength. The weakest von Frey hair that induced a reliable
activation of the afferent was defined as mechanical threshold.
If the receptive field of the afferent under study could not be
localized by gently squeezing the skin, a previously described electrical search paradigm was used (Meyer et al., 1991
). Briefly, electrical stimuli (up to 150 V, 2 msec duration) were delivered transcutaneously using a saline-soaked cotton swab as a monopolar cathodic search electrode. A needle inserted into remote distal tissue
served as the return electrode. Beginning at the distal edge of the
recording pool, the cotton swab electrode was moved distally along the
anticipated course of the peripheral nerve, thus increasing the
conduction length and conduction latency of the afferent fiber under
study. Increases in conduction latency were monotonic and continuous
until the electroreceptive field was encountered in which the
electrical threshold to activate the afferent reached a minimum and the
conduction latency decreased in discrete steps ("hopping") with
increasing stimulus intensity. The decrease in electrical threshold to
a minimum is thought to reflect activation of superficial axon
terminals, and hopping of the conduction latency may reflect activation
of different branches in the peripheral cutaneous arborization of the
nerve fiber (for details, see Peng et al., 1999
). Test locations were defined as part of the electroreceptive field whenever discrete steps
in latency were observed when the stimulation intensity was varied. To
minimize current spread across the receptive field, which might
compromise precise mapping of the electroreceptive field, the position
of the return electrode was changed during the mapping so that it was
always on the same side of the receptive field as the test electrode.
Electroreceptive spots were marked with colored ink on the skin. The
distance between the recording electrode and the receptive field was
measured along the assumed course of the nerve. The conduction latency
from the peripheral receptive field was determined at three times above
threshold and used to calculate the conduction velocity from skin.
After mapping, electroreceptive and mechanoreceptive fields were
transferred onto acetate sheets.
Testing responsiveness to mechanical stimuli. An ascending
series of von Frey probes was used to establish the mechanical threshold of each fiber. A fiber was classified as an MIA if the mechanical threshold was
6 bar. This corresponds to fibers that did
not respond to a 5.1 bar probe (0.36 mm diameter, 51 mN) but may have
responded to the next higher 7.3 bar probe (0.51 mm diameter, 98 mN).
As described previously (Meyer et al., 1991
), 6 bars is 3 SDs
above the mean threshold of C-fiber nociceptive afferents identified
with standard mechanical search techniques. Mechanically insensitive
afferents are not necessarily unresponsive to mechanical stimuli, some
can be activated by stronger mechanical stimuli (e.g., stronger von
Frey hairs, forceps pinch, or needle insertion). To avoid injuring the
receptive field, intense mechanical stimuli were not routinely used.
Testing responsiveness to heat. To test the heat
responsiveness of the afferent, contact-free heat stimuli were
delivered to the skin using a radiometer feedback-controlled carbon
dioxide laser (Meyer et al., 1976
). Because the receptive fields to be tested were often bigger than the laser diameter (8 mm), the receptive field was divided into several, nonoverlapping test areas. After a
given spot was tested, the laser was directed toward the next test
point, and testing was repeated until the complete receptive field was studied.
All heat stimuli were started from a baseline temperature of 38°C
that was held for at least 3 sec. To locate heat-sensitive spots, a
49°C stimulus of 1 or 3 sec duration was delivered to the test area.
If the afferent responded within 1 sec of the stimulus onset, the
afferent was classified as a type II afferent (Treede et al., 1998
).
Heat thresholds were determined at spots responsive to the initial
stimulus after waiting at least 3 min to allow for recovery from
possible fatigue (Treede et al., 1998
). Thresholds were determined with
1 sec duration stimuli that started from baseline (38°C) and
increased in 1°C increments until the final temperature of 49°C was
reached. Stimuli were either presented in a discrete staircase paradigm
or as an ascending series in which each step was started from baseline
and stimuli were presented 30 sec apart. Threshold was defined as the
temperature that evoked the first action potential in the afferent
under study.
As reported earlier (Treede et al., 1998
), fibers with a high heat
threshold to short-duration heat stimuli may respond to lower
temperatures when the stimulus duration is increased. Afferents unresponsive to the initial, short-lasting 49°C stimulus were therefore tested with stimuli of 30 sec duration and temperatures of
45, 47, and 49°C. If such a stimulus induced a response, the afferent
was classified as heat-insensitive with a type I response. In afferents
unresponsive to a 49°C, 30 sec stimulus, a 53°C stimulus of 30 sec
duration was finally delivered to the receptive field. To minimize
tissue injury, prolonged stimuli were administered only at a single
spot inside the electroreceptive and/or mechanoreceptive field. Two
measures were taken to avoid effects that might compromise the response
to capsaicin that followed the heat testing: (1) when feasible, the
53°C, 30 sec stimulus was presented to an area different from the
capsaicin injection site and (2) as with all stimuli of long duration
(30 sec), the stimulus was aborted when the afferent started to
respond. Afferents not responding to the 53°C, 30 sec stimulus were
regarded as heat-unresponsive, high-threshold mechanoreceptors (HTMs)
(Perl, 1968
). Responsive afferents were classified according to the
criteria reported previously (Treede et al., 1998
). Briefly, a type II
response was characterized by a rapid onset (<1 sec), an early peak
discharge (<1 sec), and an adapting response during the stimulation.
Afferents showing a late onset (>0.2 sec), a late peak discharge rate
(>2 sec), and an increasing response during the stimulation were
classified as heat-insensitive with a type I response. For stimuli that
had been aborted, the late response was used to classify the afferents as type I afferents.
For this study, all fibers with a type II heat response were considered
to be heat-sensitive afferents. All other fibers (including type I
afferents) were considered to be heat-insensitive.
Capsaicin injections. Capsaicin was prepared in Tween 80 and
saline as described earlier (LaMotte et al., 1991
). In some
experiments, Evans Blue (0.5, 1, or 4%) was added to the capsaicin
solution to delineate the spread of the injected volume. A standard
dose of 10 µg of capsaicin in a volume of 10 µl was injected with a Becton Dickinson (Franklin Lakes, NJ) LoDose syringe. The area of spread was confined within the area covered by the heat stimulus, i.e., it was <8 mm in diameter. When multiple injections were administered, the first injection was usually done 4 mm distal and
outside of the electroreceptive and mechanoreceptive fields to check
for remote effects of capsaicin. A second injection was performed
inside an area that was purely electroreceptive. In afferents with a
mechanoreceptive field, injections into this area were usually done
last. Before injection of capsaicin, any ongoing activity in the fiber
was recorded for 1 min. Insertion of the needle was followed by a
10-15 sec waiting period to ensure that insertion-related activity had
decreased before the capsaicin injection. Responses to the injection of
capsaicin were recorded for 10 min or until injection-related activity
had ceased.
Data collection. Action potentials were displayed, recorded,
and stored on a personal computer using a computer-based data acquisition board and a customized data acquisition and analysis software (DAPSYS; Brian Turnquist, Johns Hopkins University). DAPSYS
allowed on- and off-line discrimination of different action potential
waveforms based on multiple time-amplitude window criteria. In addition
to the recording of action potential waveforms, DAPSYS controlled the
laser that was used to apply heat stimuli to the skin, and it recorded
the corresponding skin temperature before, during, and after such a
stimulus. Furthermore, DAPSYS was used to time the different phases of
the injection protocol by providing an auditory signal at the
appropriate time points to start the needle insertion and the actual
injection. Recorded action potentials and events (heat and mechanical
stimuli) were time-stamped, which allowed the time course and neuronal
activity to be directly related to the manipulations performed.
Statistical analysis. STATISTICA for Windows (1997;
StatSoft, Tulsa, OK) was used for data analysis. Depending on the data to be analyzed, parametric and nonparametric procedures were used (Student's t test, ANOVA, Wilcoxon, and Mann-Whitney
U test) when appropriate. Level of significance was
p < 0.05. Data are presented as mean ± SEM.
 |
RESULTS |
A total of 57 A-nociceptors that innervated hairy skin
were studied in 45 experiments. Conduction velocities, as measured from
the nerve stimulation electrode, ranged from 4.7 to 53 m/sec (mean,
14 ± 1.2 m/sec). Fibers classified as type I heat-responsive had
significantly higher conduction velocities (18.8 ± 2.7 m/sec; n = 14) than type II fibers (11.1 ± 0.6 m/sec;
n = 21; p < 0.01; t test).
Four of the nociceptors had conduction velocities >30 m/sec and
therefore would be considered to be A
fibers; three of these had a
type I heat response, and one was an HTM. In addition, type I
heat-responsive fibers had lower mechanical thresholds (median 3.7 bar)
than type II heat-sensitive afferents (11 bar; p < 0.01; Mann-Whitney U test). These findings are consistent with a previous study (Treede et al., 1998
). Four of the type II
afferents had mechanical thresholds <6 bar, 10 type II fibers could be
excited by von Frey hairs >6 bar, five type II afferents only
responded to needle insertion or forceps squeeze, and two type II
afferents did not respond to any mechanical stimulus. MIAs had
significantly lower conduction velocities (10.5 ± 0.63 m/sec;
n = 30) than MSAs (18.0 ± 2.1 m/sec;
n = 27; p < 0.01; t test).
Table 1 summarizes some of the
characteristic features of the fibers studied.
To compare the responses to capsaicin across different fiber
populations, only the largest response to capsaicin (number of action
potentials per 10 min) in each fiber was used for analysis, regardless
of the site of injection in the receptive field. In six fibers,
capsaicin injection did not lead to excitation. Three of these
afferents (all MIA, two unresponsive to a 53°C, 30 sec stimulus, one
with heat threshold >49°C, 1 sec) were injected with capsaicin at
multiple sites inside the electrical receptive field, but none of the
administrations resulted in excitation. In the other three afferents
(all MSA, two type I, one HTM), responsiveness to capsaicin was tested
by a single injection into the receptive field.
Type II heat-responsive A-fiber nociceptors exhibit a strong
response to capsaicin
A representative response to capsaicin obtained from a type II
heat-sensitive nociceptor is illustrated in Figure
1 (left panel). Before
the injection, the afferent was silent. Although all of the type II
afferents that were injected with capsaicin were MIAs and had high
mechanical thresholds, needle insertion into the receptive field
induced a weak, short-lasting response in most of them (10 of 16) as is
evident by the example in the left panel of Figure 1. After injection
of capsaicin, the afferent exhibited a strong response with a peak
instantaneous discharge frequency of 53 Hz. Although the instantaneous
discharge frequency declined rapidly, ongoing activity at a lower
discharge rate could be observed for 9 min after the injection.

View larger version (22K):
[in this window]
[in a new window]
|
Figure 1.
Specimen recordings of a response to
capsaicin. A, Response to intradermal injection of
capsaicin (10 µg/10 µl) for a type II heat-sensitive afferent (heat
threshold, 49°C, 1 sec; mechanical threshold, 8.6 bar). The capsaicin
was injected into an area responsive to von Frey hair stimulation. The
needle insertion induced some activity in the fiber that was followed
by a strong discharge after injection of capsaicin. Activity could be
observed for 9 min after the injection. B, Response for
a type I heat-insensitive afferent (heat threshold, 53°C, 4 sec;
mechanical threshold, 4.6 bar). The capsaicin was injected into the
mechanical receptive field. The needle insertion itself induced a
strong activation. The excitation caused by the injection of capsaicin
was short-lived (<5 sec), and no further action potentials were
observed for 10 min after the injection. Top panels,
Time course of action potential activity. Every vertical
line marks the time of occurrence of an action potential.
Middle panels, Response to needle insertion and
capsaicin injection illustrated on an expanded time scale.
Bottom panels, Instantaneous frequency. Every
circle represents the instantaneous frequency and time
of occurrence of an action potential. Open triangles
indicate the time point of tone from computer to prompt needle
insertion. Filled triangles indicate the time of tone
for capsaicin injection.
|
|
The average time course of the response to an intradermal capsaicin
injection obtained from 16 type II heat-sensitive fibers is summarized
in Figure 2A. Insertion
of the needle was accompanied by weak activation in 10 afferents, but
injection of capsaicin induced a strong discharge that was
significantly larger than the activation observed by needle insertion
alone (6.3 ± 1.7 vs 53 ± 6 action potentials per minute;
repeated measures ANOVA followed by Scheffé test;
p < 0.001). The discharge induced during the first
minute after the injection was also significantly larger than the
discharge observed thereafter (p < 0.001). As
illustrated in Figure 3A, the
most vigorous activation occurred during the first 15 sec after the
start of the injection. This injection-induced discharge was
significantly larger than the activation caused by needle insertion
alone (46 ± 7 vs 6 ± 1.7 action potentials per 15 sec;
n = 16; p < 0.001; paired t
test).

View larger version (25K):
[in this window]
[in a new window]
|
Figure 2.
Average time course of capsaicin-evoked responses.
A, Fibers with a type II heat response
(n = 16). Type II fibers showed a strong response
to capsaicin injection and only a weak response to needle insertion.
B, Subset of heat-insensitive afferents with a vigorous
response to capsaicin. These afferents (n = 5) were
not type II heat-sensitive afferents but responded with >100 action
potentials per 10 min to capsaicin injection. Open bars
indicate the response to needle insertion, and filled
bars represent the response to capsaicin (bin size = 1 min). Inset, Expanded display at time of injection (bin
size = 15 sec).
|
|

View larger version (11K):
[in this window]
[in a new window]
|
Figure 3.
Comparison of the responses to needle insertion
and the responses during the first 15 sec after the capsaicin
injection. A, Type II heat-sensitive afferents. The
response after capsaicin injection was significantly larger than the
response to needle insertion alone (p < 0.001; paired t test; n = 16).
B, Heat-insensitive afferents. In these afferents,
capsaicin injection did not lead to a significantly larger response
than needle insertion alone (n = 24). The five
heat-insensitive afferents that did not respond to capsaicin are
excluded.
|
|
A histogram of the total response during the 10 min after the capsaicin
injection is shown in Figure
4A. All type II fibers responded to capsaicin. The majority of fibers (13 of 16) responded with >50 action potentials in 10 min, and only 3 of 16 responded with
<40 action potentials in 10 min. The average response in type II
heat-sensitive nociceptive fibers was 69 ± 7 action potentials per 10 min.

View larger version (17K):
[in this window]
[in a new window]
|
Figure 4.
Distribution of the total response to
capsaicin in 10 min. A, Type II heat-sensitive
afferents. All type II fibers gave a response to capsaicin that was
>20 action potentials in 10 min (dashed line). In fact,
the majority of fibers exhibited a strong response to capsaicin (>50
action potentials in 10 min). B, Heat-insensitive
afferents. The majority of fibers categorized as HTM, type I, or not
type II had very weak responses to capsaicin ( 20 action potentials
per 10 min). However, five fibers not showing a type II response to
heat showed the most vigorous responses to capsaicin (>100 action
potentials per 10 min). Note: stacked histogram.
|
|
Most heat-insensitive afferents are capsaicin-insensitive
An example of the response of a heat-insensitive afferent to
capsaicin is shown in Figure 1B (right
panel). This afferent was characterized as a type I fiber
because it responded to heat only when exposed to a long-lasting 53°C
stimulus. Before needle insertion, the afferent was silent. Insertion
of the needle induced a strong response with an instantaneous frequency
of 50 Hz. In contrast, the peak discharge induced by the capsaicin
injection (30 Hz) was less than that induced by needle insertion alone. Furthermore, the injection-induced discharge quickly dissipated within
5 sec, and no further action potentials were recorded for 10 min after
the injection. In contrast to type II heat-sensitive afferents, the
activation in heat-insensitive afferents during the first 15 sec after
the start of the capsaicin injection did not significantly differ from
the activation caused by needle insertion alone (Fig.
3B).
Figure 4B shows the distribution of the capsaicin
responses obtained from fibers that did not show a type II heat
response and that were therefore classified as heat-insensitive.
Heat-insensitive fibers included type I afferents (n = 13), HTM afferents (n = 11), and those afferents that
did not show a type II heat response but were insufficiently tested for
subclassification as a type I or HTM (n = 5). The
majority of fibers (22 of 29) classified as heat-insensitive showed
only a weak response to capsaicin (<20 action potentials per 10 min)
(Fig. 4B, dashed line).
Some heat-insensitive afferents are capsaicin-sensitive
As can be seen from Figure 4B, five of the
heat-insensitive nociceptive afferents were vigorously excited by
capsaicin (>100 action potentials per 10 min). An example of a
capsaicin response in such a fiber is given in Figure
5. This afferent did not respond to
short-duration (1 sec) heat stimuli up to 49°C but responded to two
applications of a 49°C, 30 sec heat stimulus with latencies to the
first action potential of 10 and 12 sec. This afferent was therefore
classified as a type I afferent (mechanical threshold, 2.46 bar).
Figure 5A shows the response to injection of the
vehicle into the mechanoreceptive field. The afferent responded with a few action potentials to needle insertion, but no response was seen
during the 10 min after the injection of the vehicle. Figure 5B illustrates the response after capsaicin injection
into another part of the mechanoreceptive field. Again, the afferent
responded with a few action potentials to the needle insertion. In
contrast to the injection of the vehicle, capsaicin injection was
followed by a vigorous response, and this response lasted >10 min. Of
the other four afferents that showed a vigorous response to capsaicin (>100 action potentials per 10 min), two afferents did not respond to
a 53°C, 1 sec thermal stimulus and thus were not type II afferents; another two afferents were unresponsive to the 53°C, 30 sec stimulus and thus were HTMs.

View larger version (20K):
[in this window]
[in a new window]
|
Figure 5.
Vigorous response to capsaicin in a
heat-insensitive afferent. A, Response to vehicle.
B, Response to capsaicin. This afferent
(mechanical threshold = 2.46 bar) did not respond to
short-duration heat stimuli (1 sec) up to 49°C. However, the afferent
responded to a long-lasting stimulus (49°C, 30 sec) and was therefore
classified as a type I, heat-insensitive afferent. Both injections were
performed inside the mechanosensitive receptive field, and the
injection of vehicle preceded the injection of capsaicin. Insertion of
the needle induced activity in the afferent for both injections.
However, only the injection of capsaicin induced lasting activation of
the afferent. Same format as Figure 1.
|
|
Figure 2B illustrates the time course of
capsaicin-induced response for these five afferents insensitive to
heat. In contrast to the time course of response seen in type II
afferents (Fig. 2A), the response in these
heat-insensitive afferents was long-lasting, i.e., the response did not
markedly decrease during the 10 min observation period. Thus,
responsiveness to capsaicin can exist in afferents that are insensitive
to heat.
Mechanically insensitive afferents exhibit a strong response
to capsaicin
The previous analysis separated the data into two populations
based on heat sensitivity. Nociceptors may also be separated into MSAs
and MIAs based on a mechanical threshold of 6 bar (Meyer et al.,
1991
;Treede et al., 1998
).
Figure 1 also illustrates representative responses to capsaicin
observed in a fiber classified as an MIA (panel A, left
side) or an MSA (panel B, right side). The
capsaicin-induced activity was much more pronounced in the MIA than the
MSA. Figure 6 illustrates the time course
of the average responses obtained for the MIA and MSA populations based
on the largest response observed in each afferent that gave a response
to the capsaicin injection (n = 40). In MSAs, needle
insertion itself induced a stronger discharge than the injection of
capsaicin. In contrast, needle insertion induced only a weak discharge
in MIAs that was followed by a significantly larger discharge after
injection of capsaicin. Excitation during the first minute after the
injection was significantly stronger in MIAs (50 ± 7 action
potentials per minute) than in MSAs (13 ± 3 action potentials per
minute; p < 0.001; Scheffé test). In both fiber
populations, an ongoing discharge could be observed for 10 min after
the injection, and this discharge tended to be larger in MIAs.

View larger version (30K):
[in this window]
[in a new window]
|
Figure 6.
Time course of the capsaicin response in
mechanically sensitive (gray columns) and
mechanically insensitive (black columns) afferents. In
mechanically sensitive afferents (n = 18), needle
insertion itself produced the largest response. In contrast, the
largest discharge in mechanically insensitive afferents
(n = 22) was observed during the first minute after
injection of capsaicin. The response to capsaicin was significantly
larger in mechanically insensitive than mechanically sensitive
afferents (p < 0.001; two-way ANOVA with
repeated measures followed by multiple t tests with
Bonferroni correction). The six afferents (three MIAs, three MSAs) that
did not respond at all to the capsaicin injection are excluded.
|
|
The distribution of the total number of action potentials observed
during the 10 min period after the injection appeared to have two peaks
(Fig. 7A), i.e., weak
responders (
20 action potentials per 10 min) and strong responders
(>20 action potentials/10 min). According to this criterion, 23 fibers
were weak responders, and 23 were strong responders. All but two MSAs
responded weakly. Most (17 of 19) of the fibers with high responses
were MIAs (Fig. 7A). As illustrated in Figure 7B,
the total response in MIAs (103 ± 28 action potentials per 10 min) was significantly larger than in MSAs (18 ± 6 action
potentials per 10 min; p < 0.02; t test). These findings show that mechanically insensitive afferent nerve fibers
are more sensitive to capsaicin than mechanically sensitive afferents.

View larger version (15K):
[in this window]
[in a new window]
|
Figure 7.
Comparison of capsaicin responses in mechanically
sensitive and mechanically insensitive afferents. A,
Histogram for the total number of action potentials observed in 10 min
after the injection of capsaicin. Only the largest response to
capsaicin obtained in each fiber was included (n = 46). Most of the vigorous responses (>50 action potentials per 10 min)
were observed in fibers classified as mechanically insensitive.
B, Average response of the population during the 10 min.
Mechanically insensitive afferents exhibited a significantly greater
response to capsaicin than mechanically sensitive afferents
(p < 0.05; t test).
Numbers in parentheses give the number of
fibers in each group.
|
|
Responsiveness to different stimulus modalities is not equally
distributed across the receptive field
Figure 8 depicts an example in which
multiple capsaicin injections were performed in the electroreceptive
and mechanoreceptive fields of an afferent fiber. The circles indicate
areas in which mechanical (15 bar von Frey), heat (49°C, 1 sec),
and/or capsaicin (10 µg/10 µl) testing was performed. Only two
areas responded to heat. One area that was located in a purely
electroreceptive part responded to a 49°C, 1 sec heat stimulus, and
the fiber was therefore classified as type II. At the second site,
which was located in the mechanoreceptive field, a type II-like heat
response was obtained to a 53°C, 30 sec stimulus. In contrast to the
heat stimuli, capsaicin excited the afferent at all injection sites, including those unresponsive to short duration heat stimuli.
Capsaicin-induced activity ranged from 20 to 93 action potentials in 10 min, and the highest response was observed in the part of the
mechanoreceptive field unresponsive to the 49°C, 1 sec heat stimulus.

View larger version (31K):
[in this window]
[in a new window]
|
Figure 8.
Responsiveness to different stimulus modalities
varies across the receptive field of a type II fiber. The
mechanosensitive receptive field (gray area) and
the electroreceptive field (dotted line) are indicated.
Multiple test sites indicated by the circles were tested
with different stimulus modalities (heat, mechanical, capsaicin). The
size of the circle corresponds to size of the laser beam
used for the heat testing. Capsaicin induced a response at all
injection sites, whereas only two test sites were heat-sensitive.
Responses to needle insertion were observed in two locations inside the
continuous mechanoreceptive field. This afferent was characterized as
type II heat-sensitive with a heat threshold of 49°C, 1 sec and a
mechanical threshold of 11.2 bar.
|
|
Figure 9 summarizes the incidence of
mechanical, heat, and capsaicin sensitivity for sites in type II
fibers tested with all three stimulus modalities. Most of the test
sites (24 of 36) responded to only one (12) or two (12) modalities.
Only eight sites were sensitive to all three stimulus modalities. The
majority of test sites (29 of 36) were chemosensitive. Eleven test
sites were sensitive to capsaicin, but not to heat or mechanical
stimuli. In the other 10 sites, sensitivity to capsaicin was present
together with sensitivity to only one other stimulus modality. These
findings argue that different areas inside the receptive field of
polymodal nociceptors vary in their sensitivity to mechanical, thermal,
and chemical stimuli.

View larger version (11K):
[in this window]
[in a new window]
|
Figure 9.
Polymodality of different sites within the
receptive field of type II afferents. Venn diagram for the different
stimulus modalities to which a test site inside the electroreceptive
field of a type II fiber was sensitive. Only sites tested with all
three modalities are included. As for Figure 8, a test site was
classified as mechanosensitive when it responded to von Frey hair
stimulation. Most test sites were responsive to capsaicin (29 of 32),
and many of these were sensitive to capsaicin only (11 of 29). Only
eight capsaicin-sensitive sites were also sensitive to heat and
mechanical stimuli. Four sites were insensitive to each of the stimulus
modalities. Data come from 15 type II afferents.
|
|
More than one capsaicin injection into the electroreceptive and/or
mechanoreceptive field was administered for 28 fibers in this study.
Repetitive injections into electroreceptive areas of the receptive
field yielded a wide range of responses that were not significantly
different from each other. In addition, multiple injections into the
mechanosensitive receptive field resulted in similar response
magnitudes. For nine fibers, an injection was made into an
electroreceptive and a mechanosensitive area of the receptive field.
Five of these afferents were MIAs, and four were MSAs. The responses
from the mechanosensitive areas (37 ± 11 action potentials per 10 min) were significantly larger than those from purely electroreceptive
parts of the receptive field (13 ± 8 action potentials per 10 min; p < 0.05; paired t test).
Eleven capsaicin injections were made outside the electroreceptive
field. Eight of these resulted in no response. For the three injections
that resulted in a weak response (<20 action potentials in 10 min),
the Evans Blue had clearly spread into the receptive field. This
provides evidence that the electroreceptive field mapping procedure
delineated the border of the receptive field.
 |
DISCUSSION |
The results of this study provide evidence for the existence of
capsaicin-sensitive vanilloid receptors in small myelinated nociceptive
afferents of the primate. Most capsaicin-sensitive afferents were
responsive to heat but insensitive to mechanical stimuli. However, heat
sensitivity was not a prerequisite for responsiveness to capsaicin,
because vigorous excitation by capsaicin was observed in some
heat-insensitive afferents. Moreover, within the receptive field of a
given heat-sensitive A-fiber nociceptor, regions responsive to heat did
not always correspond to regions responsive to capsaicin.
Capsaicin activates heat-sensitive type II A-fiber nociceptors
In this study all cutaneous type II heat-sensitive A-fiber
nociceptors (16 of 16) were excited by capsaicin, providing for the
first time direct evidence that vanilloid receptors are present in the
axonal membrane of these cutaneous afferents. Earlier psychophysical experiments provided indirect evidence that capsaicin sensitivity may
exist in A-fiber nociceptors. Type II A-fiber nociceptors in human skin
mediate the first pricking sensation to stepped heat stimuli (Price et
al., 1977
; Campbell and LaMotte, 1983
; Gronroos et al., 1996
). The loss
of the first heat pain and the corresponding evoked potential after
repetitive topical capsaicin treatment suggest that type II A-fiber
nociceptors become desensitized by capsaicin and therefore are indeed
capsaicin-sensitive (Beydoun et al., 1996
; Gronroos et al., 1996
). In
addition, the administration of a capsaicin analog produced heat
analgesia in human skin (Davis et al., 1995a
,b
), and administration of
capsaicin resulted in a dramatic increase in the latency for the
detection of heat pain (Nolano et al., 1999
).
Of the vanilloid receptors identified so far, only one has been
reported to be responsive to capsaicin. The VR1 is responsive to heat
and to capsaicin, protons, and resiniferatoxin (Caterina et al., 1997
;
Tominaga et al., 1998
). A splice variant of VR1, VR.5'sv, is completely
unresponsive to these stimuli (Schumacher et al., 2000
). Furthermore,
the VRL1 only responds to high-intensity heat stimuli but not to
chemical stimuli such as capsaicin, resiniferatoxin, and protons
(Caterina et al., 1999
). The VR1 appears to be the critical
transduction protein that mediates responses to capsaicin because
afferent neurons from VR1-null mutant mice do not respond to capsaicin,
and null mutant animals do not display pain behavior after capsaicin
injection (Caterina et al., 2000
). This suggests that only VR1 could
account for the capsaicin sensitivity in heat-sensitive A-fiber
nociceptors. In previous studies in rat, however, VR1 has only been
localized in small-diameter neurons that are connected to small
unmyelinated fibers in the periphery (Caterina et al., 1997
). Two
explanations may explain this apparent discrepancy: (1) in primate, the
expression of VR1 may not be limited to small-diameter neurons but may
also extend to medium- and large-diameter neurons. (2) Responses to
capsaicin in A-fiber nociceptors may be mediated by yet unidentified
vanilloid receptor splice variants of VR1 other than VR.5'sv.
Capsaicin sensitivity without heat sensitivity
One surprising finding of the present study was that some A-fiber
nociceptors were insensitive to heat but responsive to capsaicin. In
fact, the highest responses to capsaicin were observed in these afferents. These A-fiber nociceptors were also insensitive to mechanical stimuli. Thus, some A-fiber nociceptors may be considered to
be cutaneous chemoreceptors. In support of this idea, A-fiber nociceptors were also found to give a more vigorous response to intradermal injection of a cocktail of inflammatory mediators than did
C-fiber nociceptors (Davis et al., 1993
).
Capsaicin sensitivity in heat-insensitive dorsal root ganglion cells
has previously been reported (Kirschstein et al., 1997
, 1999
). As in
the present study, however, the prevalence of capsaicin sensitivity in
heat-insensitive afferent neurons was low (2 of 5 and 2 of 14). In
contrast, recordings from dorsal root ganglion cells in rat
demonstrated that sensitivity to capsaicin is restricted to neurons
with a low heat threshold (Nagy and Rang, 1999a
). It could be argued
that the capsaicin responses in heat-insensitive afferents reported
here are attributable to an unspecified capsaicin effect. This is
unlikely, however, because a strong excitation by capsaicin was
primarily observed in mechanically insensitive afferents (Fig. 6),
whereas excitation caused by an unspecified effect should have been
observed across different classes of afferents. Patch-clamp experiments
on isolated membrane patches have recently shown that ion channels may
be exclusively activated by either capsaicin or heat. Surprisingly,
sensitivity to only one stimulus modality was more frequently observed
than sensitivity to both (Nagy and Rang, 1999b
). Therefore, the VR1 may
be present in different molecular configurations that differ in their
sensitivity to heat and capsaicin (Nagy and Rang, 1999b
). It is
plausible that such a segregation may be present in the entire axonal
membrane of a neuron.
Most type I afferents are not responsive to capsaicin
The VRL1 is activated by high heat intensities but not capsaicin
(Caterina et al., 1999
). In rat, the VRL1, and not the VR1, receptor is
found in medium- to large-diameter neurons. Our finding that most (11 of 13) type I A-fiber nociceptors did not respond to capsaicin is
consistent with the hypothesis that the VRL1 receptor is responsible
for heat transduction in this class of afferents.
Role of capsaicin-sensitive A-fiber nociceptors
Intradermal injection of capsaicin in humans produces intense pain
and leads to secondary hyperalgesia to mechanical stimuli (LaMotte et
al., 1991
; Ali et al., 1996
; Huang et al., 2000
). Pain and hyperalgesia
develop in the presence of an A-fiber block and thus are thought to be
attributable mainly to activation of C-fiber nociceptors (Ziegler et
al., 1999
). However, the A-fiber block experiments do not rule out a
role for the A-fiber nociceptors because many A-nociceptors have very
long unmyelinated branches that may extend beyond a radial nerve
compression block (Peng et al., 1999
).
Mechanically insensitive afferents are excited by capsaicin
The results of this study also demonstrate that afferents
insensitive to mechanical stimuli are sensitive to capsaicin. In contrast to mechanically sensitive afferents, mechanically insensitive afferents exhibit a strong response to the capsaicin injection but only
a weak response to needle insertion. Almost all responses to capsaicin
in this study were obtained in mechanically insensitive afferents. In
conjunction with the observation that type II heat-sensitive fibers are
capsaicin-sensitive, this finding is not surprising but consistent with
an earlier study showing that type II heat-sensitive fibers are in fact
insensitive to mechanical stimuli (Treede et al., 1998
). Interestingly,
a similar finding has been reported from microneurography experiments
in humans showing that unmyelinated C-fibers insensitive to mechanical
stimuli are vigorously activated by capsaicin (Schmelz et al., 2000
).
The fact that capsaicin-sensitive fibers are insensitive to mechanical
stimuli (including gentle pinching the skin) may explain why previous
studies that used mechanical search techniques to locate receptive
fields failed to identify these capsaicin responders (Szolcsanyi et
al., 1988
; Baumann et al., 1991
). In the present study, a previously
described electrical search technique (Meyer et al., 1991
) was used to
locate receptive fields.
Sensitivity to different stimulus modalities does not coincide
within the receptive field
Most of the test sites (24 of 36) in type II heat-sensitive
afferents responded to only one or two stimulus modalities. Sensitivity to all three modalities was observed at only eight test sites. This
finding suggests that A-fiber nociceptors are not homogeneously responsive to different stimulus modalities across their innervation territory.
In a previous study, we reported that mechanical and heat sensitivity
were colocalized for unmyelinated nociceptive fibers (Treede et al.,
1990
). However, in that study only unmyelinated fibers were
investigated, and receptive fields were not mapped with electrical
stimuli. Therefore, heat-sensitive but mechanoinsensitive sites might
have been overlooked. In fact, a mismatch between spots sensitive to
heat and mechanical stimuli has been reported for nociceptive C-fibers
in humans (Olausson, 1998
).
Sensitivity to a given stimulus ultimately depends on the presence of
functional transduction proteins in the axonal membranes of the
peripheral endings. Most likely, the transduction proteins responsive
to different stimulus modalities are randomly distributed along the
axon and its peripheral terminals. Sensitivity to a certain stimulus,
however, may depend on the density of functional channels in the
membrane, and this density may vary along the peripheral arborization
of a given fiber.
 |
FOOTNOTES |
Received Dec. 27, 2000; revised March 12, 2001; accepted March 26, 2001.
This research was supported by National Institutes of Health Grant NS
14447. We appreciate the technical assistance of Sylvia Horasek.
Correspondence should be addressed to Richard A. Meyer, Department of
Neurosurgery, School of Medicine, Johns Hopkins University, Meyer
5-109, 600 North Wolfe Street, Baltimore, MD 21287. E-mail: rmeyer{at}jhmi.edu.
 |
REFERENCES |
-
Ali Z,
Meyer RA,
Campbell JN
(1996)
Secondary hyperalgesia to mechanical but not heat stimuli following a capsaicin injection in hairy skin.
Pain
68:401-411[ISI][Medline].
-
Baumann TK,
Simone DA,
Shain CN,
LaMotte RH
(1991)
Neurogenic hyperalgesia: the search for the primary cutaneous afferent fibers that contribute to capsaicin-induced pain and hyperalgesia.
J Neurophysiol
66:212-227[Abstract/Free Full Text].
-
Beydoun A,
Dyke DBS,
Morrow TJ,
Casey KL
(1996)
Topical capsaicin selectively attenuates heat pain and A
fiber-mediated laser-evoked potentials.
Pain
65:189-196[ISI][Medline]. -
Campbell JN,
LaMotte RH
(1983)
Latency to detection of first pain.
Brain Res
266:203-208[ISI][Medline].
-
Campbell JN,
Meyer RA
(1983)
Sensitization of unmyelinated nociceptive afferents in the monkey varies with skin type.
J Neurophysiol
49:98-110[Free Full Text].
-
Caterina MJ,
Schumacher MA,
Tominaga M,
Rosen TA,
Levine JD,
Julius D
(1997)
The capsaicin receptor: a heat-activated ion channel in the pain pathway.
Nature
389:816-824[Medline].
-
Caterina MJ,
Rosen TA,
Tominaga M,
Brake AJ,
Julius D
(1999)
A capsaicin-receptor homologue with a high threshold for noxious heat.
Nature
398:436-441[Medline].
-
Caterina MJ,
Leffler A,
Malmberg AB,
Martin WJ,
Trafton J,
Petersen-Zeitz KR,
Koltzenburg M,
Basbaum AI,
Julius D
(2000)
Impaired nociception and pain sensation in mice lacking the capsaicin receptor.
Science
288:306-313[Abstract/Free Full Text].
-
Davis KD,
Meyer RA,
Campbell JN
(1993)
Chemosensitivity and sensitization of nociceptive afferents that innervate the hairy skin of monkey.
J Neurophysiol
69:1071-1081[Abstract/Free Full Text].
-
Davis KD,
Meyer RA,
Turnquist JL,
Filloon TG,
Pappagallo M,
Campbell JN
(1995a)
Cutaneous injection of the capsaicin analogue, NE-21610, produces analgesia to heat but not to mechanical stimuli in man.
Pain
61:17-26[Medline].
-
Davis KD,
Meyer RA,
Turnquist JL,
Filloon TG,
Pappagallo M,
Campbell JN
(1995b)
Cutaneous pretreatment with the capsaicin analog NE-21610 prevents the pain to a burn and subsequent hyperalgesia.
Pain
62:373-378[ISI][Medline].
-
Gronroos M,
Reunala T,
Pertovaara A
(1996)
Influence of selective nerve fiber blocks on argon laser-induced thermal pain in the human skin.
Neurosci Lett
211:143-145[Medline].
-
Huang JH,
Ali Z,
Travison TG,
Campbell JN,
Meyer RA
(2000)
Spatial mapping of the zone of secondary hyperalgesia reveals a gradual decline of pain with distance but sharp borders.
Pain
86:33-42[Medline].
-
Kirschstein T,
Busselberg D,
Treede RD
(1997)
Coexpression of heat-evoked and capsaicin-evoked inward currents in acutely dissociated rat dorsal root ganglion neurons.
Neurosci Lett
231:33-36[ISI][Medline].
-
Kirschstein T,
Greffrath W,
Busselberg D,
Treede RD
(1999)
Inhibition of rapid heat responses in nociceptive primary sensory neurons of rats by vanilloid receptor antagonists.
J Neurophysiol
82:2853-2860[Abstract/Free Full Text].
-
LaMotte RH,
Shain CN,
Simone DA,
Tsai E-FP
(1991)
Neurogenic hyperalgesia: Psychophysical studies of underlying mechanisms.
J Neurophysiol
66:190-211[Abstract/Free Full Text].
-
Meyer RA,
Walker RE,
Mountcastle VB
(1976)
A laser stimulator for the study of cutaneous thermal pain sensation.
IEEE Trans Biomed Eng
23:54-60[ISI][Medline].
-
Meyer RA,
Davis KD,
Cohen RH,
Treede R-D,
Campbell JN
(1991)
Mechanically insensitive afferents (MIAs) in cutaneous nerves of monkey.
Brain Res
561:252-261[ISI][Medline].
-
Nagy I,
Rang H
(1999a)
Noxious heat activates all capsaicin-sensitive and also a subpopulation of capsaicin-insensitive dorsal root ganglion neurons.
Neuroscience
88:995-997[ISI][Medline].
-
Nagy I,
Rang HP
(1999b)
Similarities and differences between the responses of rat sensory neurons to noxious heat and capsaicin.
J Neurosci
19:10647-10655[Abstract/Free Full Text].
-
Nolano M,
Simone DA,
Wendelschafer-Crabb G,
Johnson T,
Hazen E,
Kennedy WR
(1999)
Topical capsaicin in humans: parallel loss of epidermal nerve fibers and pain sensation.
Pain
81:135-145[ISI][Medline].
-
Olausson B
(1998)
Recordings of polymodal single C-fiber nociceptive afferents following mechanical and argon-laser heat stimulation of human skin.
Exp Brain Res
122:44-54[ISI][Medline].
-
Peng YB,
Ringkamp M,
Campbell JN,
Meyer RA
(1999)
Electrophysiological assessment of the cutaneous arborization of A-delta-fiber nociceptors.
J Neurophysiol
82:1164-1177[Abstract/Free Full Text].
-
Perl ER
(1968)
Myelinated afferent fibres innervating the primate skin and their response to noxious stimuli.
J Physiol (Lond)
197:593-615[Abstract/Free Full Text].
-
Price DD,
Hu JW,
Dubner R,
Gracely RH
(1977)
Peripheral suppression of first pain and central summation of second pain evoked by noxious heat pulses.
Pain
3:57-68[ISI][Medline].
-
Schmelz M,
Schmidt R,
Handwerker HO,
Torebjörk HE
(2000)
Encoding of burning pain from capsaicin-treated human skin in two categories of unmyelinated nerve fibres.
Brain
123(Pt 3):560-571[Abstract/Free Full Text].
-
Schumacher MA,
Moff I,
Sudanagunta SP,
Levine JD
(2000)
Molecular cloning of an N-terminal splice variant of the capsaicin receptor. Loss of N-terminal domain suggests functional divergence among capsaicin receptor subtypes.
J Biol Chem
275:2756-2762[Abstract/Free Full Text].
-
Szolcsanyi J,
Anton F,
Reeh PW,
Handwerker H
(1988)
Selective excitation by capsaicin of mechano-heat sensitive nociceptors in rat skin.
Brain Res
446:262-268[ISI][Medline].
-
Tominaga M,
Caterina MJ,
Malmberg AB,
Rosen TA,
Gilbert H,
Skinner K,
Raumann BE,
Basbaum AI,
Julius D
(1998)
The cloned capsaicin receptor integrates multiple pain-producing stimuli.
Neuron
21:531-543[ISI][Medline].
-
Treede R-D,
Meyer RA,
Campbell JN
(1990)
Comparison of heat and mechanical receptive fields of cutaneous C-fiber nociceptors in monkey.
J Neurophysiol
64:1502-1513[Abstract/Free Full Text].
-
Treede RD,
Meyer RA,
Raja SN,
Campbell JN
(1995)
Evidence for two different heat transduction mechanisms in nociceptive primary afferents innervating monkey skin.
J Physiology
483:747-758[ISI][Medline].
-
Treede R-D,
Campbell JN,
Meyer RA
(1998)
Myelinated mechanically-insensitive afferents from monkey hairy skin: heat response properties.
J Neurophysiol
80:1082-1093[Abstract/Free Full Text].
-
Ziegler EA,
Magerl W,
Meyer RA,
Treede RD
(1999)
Secondary hyperalgesia to punctate mechanical stimuli. Central sensitization to A-fibre nociceptor input.
Brain
122(Pt 12):2245-2257[Abstract/Free Full Text].
Copyright © 2001 Society for Neuroscience 0270-6474/01/21124460-09$05.00/0
This article has been cited by other articles:

|
 |

|
 |
 
S. Davidson, X. Zhang, S. G. Khasabov, D. A. Simone, and G. J. Giesler Jr.
Termination Zones of Functionally Characterized Spinothalamic Tract Neurons Within the Primate Posterior Thalamus
J Neurophysiol,
October 1, 2008;
100(4):
2026 - 2037.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. K. Rau, N. Jiang, R. D. Johnson, and B. Y. Cooper
Heat Sensitization in Skin and Muscle Nociceptors Expressing Distinct Combinations of TRPV1 and TRPV2 Protein
J Neurophysiol,
April 1, 2007;
97(4):
2651 - 2662.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. K. Rau, R. D. Johnson, and B. Y. Cooper
Nicotinic AChR in Subclassified Capsaicin-Sensitive and -Insensitive Nociceptors of the Rat DRG
J Neurophysiol,
March 1, 2005;
93(3):
1358 - 1371.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. N. Doan, K. Stephans, A. N. Ramirez, P. A. Glazebrook, M. C. Andresen, and D. L. Kunze
Differential Distribution and Function of Hyperpolarization-Activated Channels in Sensory Neurons and Mechanosensitive Fibers
J. Neurosci.,
March 31, 2004;
24(13):
3335 - 3343.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. A. Munce and W. L. Kenney
Age-specific modification of local cutaneous vasodilation by capsaicin-sensitive primary afferents
J Appl Physiol,
September 1, 2003;
95(3):
1016 - 1024.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Klede, H. O. Handwerker, and M. Schmelz
Central Origin of Secondary Mechanical Hyperalgesia
J Neurophysiol,
July 1, 2003;
90(1):
353 - 359.
[Abstract]
[Full Text]
[PDF]
|
 |
|