Abstract
Mammalian hearing sensitivity and frequency selectivity depend on a mechanical amplification process mediated by outer hair cells (OHCs). OHCs are situated within the organ of Corti atop the basilar membrane (BM), which supports sound-evoked traveling waves. It is well established that OHCs generate force to selectively amplify BM traveling waves where they peak, and that amplification accumulates from one location to the next over this narrow cochlear region. However, recent measurements demonstrate that traveling waves along the apical surface of the organ of Corti, the reticular lamina (RL), are amplified over a much broader region. Whether OHC forces accumulate along the length of the RL traveling wave to provide a form of “global” cochlear amplification is unclear. Here we examined the spatial accumulation of RL amplification. In mice of either sex, we used tones to suppress amplification from different cochlear regions and examined the effect on RL vibrations near and far from the traveling-wave peak. We found that although OHC forces amplify the entire RL traveling wave, amplification only accumulates near the peak, over the same region where BM motion is amplified. This contradicts the notion that RL motion is involved in a global amplification mechanism and reveals that the mechanical properties of the BM and organ of Corti tune how OHC forces accumulate spatially. Restricting the spatial buildup of amplification enhances frequency selectivity by sharpening the peaks of cochlear traveling waves and constrains the number of OHCs responsible for mechanical sensitivity at each location.
SIGNIFICANCE STATEMENT Outer hair cells generate force to amplify traveling waves within the mammalian cochlea. This force generation is critical to the ability to detect and discriminate sounds. Nevertheless, how these forces couple to the motions of the surrounding structures and integrate along the cochlear length remains poorly understood. Here we demonstrate that outer hair cell-generated forces amplify traveling-wave motion on the organ of Corti throughout the wave's extent, but that these forces only accumulate longitudinally over a region near the wave's peak. The longitudinal coupling of outer hair cell-generated forces is therefore spatially tuned, likely by the mechanical properties of the basilar membrane and organ of Corti. Our findings provide new insight into the mechanical processes that underlie sensitive hearing.
Introduction
Sound stimulation of the mammalian inner ear evokes a displacement wave on the basilar membrane (BM) that travels from the cochlear base to apex. Each longitudinal BM location is tuned to a different characteristic frequency (CF), such that high-frequency sounds elicit waves that peak near the base, and low frequencies elicit waves that peak more apically (Békésy, 1960). As the wave propagates, its magnitude is amplified by forces generated by the outer hair cells (OHCs) within the organ of Corti (Oghalai, 2004; Ashmore et al., 2010; Fig. 1A–C). Amplification of BM motion becomes apparent a short distance basal to the wave's peak and accumulates spatially as the wave travels over the amplifying region (Russell and Nilsen, 1997; Rhode and Recio, 2000; Ren, 2002). The gain at the peak is therefore partially inherited from OHC activity at more basal locations, and damaging or disturbing OHCs anywhere within the amplifying region can reduce the wave's peak magnitude (Cody, 1992; Rhode, 2007; Fisher et al., 2012; Versteegh and van der Heijden, 2013). The buildup of BM amplification over a restricted region is thought to underlie the high sensitivity and sharp frequency tuning of responses measured from inner hair cells (IHCs), the primary afferent receptors, and auditory nerve fibers in high-frequency regions of the mammalian cochlea (Patuzzi and Robertson, 1988; Narayan et al., 1998).
Recent measurements, however, demonstrate that traveling-wave motion on the reticular lamina (RL), at the apical surface of the OHCs, is quite different from BM motion (Lee et al., 2016; Ren et al., 2016b; Cooper et al., 2018). RL traveling waves are amplified over a much broader spatial region, perhaps extending throughout the cochlear base. At a given location, RL motion is therefore not just amplified at the CF, but also at frequencies several octaves lower. These new data suggest that BM motion provides an incomplete description of cochlear mechanics and raise important questions regarding the functional role of below-CF RL amplification. Although it has been proposed that amplification of the RL traveling wave distant from the peak underlies a global hydrodynamic mechanism for building up the wave as it propagates (Ren et al., 2016b; He et al., 2018), the buildup of RL amplification has not yet been assessed.
Here we examined how RL traveling-wave amplification builds up in the mouse cochlear apex. To do so, we studied how tone-evoked BM and RL vibrations were suppressed by the presentation of a second tone. Suppression occurs when the response to one tone saturates OHC mechanotransduction currents, thus limiting OHC force generation (Geisler et al., 1990). By varying the suppressor tone frequency, we selectively reduced amplification from different cochlear locations, allowing us to map the region where amplification accumulates (which we term the “buildup region”). Previous measurements have shown that the BM traveling-wave peak can be suppressed by tones that excite any region where the wave is amplified, consistent with amplification building up over the amplifying region (Rhode, 2007; Versteegh and van der Heijden, 2013; Fig. 1C–F). If this also holds true for the RL traveling wave, RL amplification would build up over the entire cochlea, because the RL's amplifying region extends to the cochlear base. RL motion near or distant from the peak should be reduced by a wide range of suppressor frequencies, including those that stimulate locations far basal to the peak (Fig. 1G–J). If the extreme opposite scenario were true and RL amplification did not build up at all, RL motion should only be suppressed by tones that stimulate OHCs at the measurement site (Fig. 1K–N).
Interestingly, our measurements reveal an intermediate scenario in which RL traveling-wave amplification primarily builds up near the wave's peak, with a buildup region similar to that observed for the BM. These data suggest that the coupling of OHC-generated forces along the RL and BM is spatially tuned, likely by the mechanical properties of the BM and organ of Corti.
Materials and Methods
Mouse preparation.
We measured cochlear vibrations in vivo in adult (4- to 6-week-old) wild-type CBA/CaJ mice (stock #000654, The Jackson Laboratory) of either sex (n = 10; 5 male). All procedures were approved by the Institutional Animal Care and Use Committee at the University of Southern California. Mice were anesthetized with ketamine (80–100 mg/kg) and xylazine (5–10 mg/kg) and positioned on a heating pad to maintain a core body temperature of ∼37°C. Supplemental doses of anesthesia were administered throughout the experiment to ensure areflexia. The top of the skull was exposed and glued to a custom head-holder using dental cement, and a ventrolateral approach was used to surgically access the left middle ear bulla. The bone below the tympanic ring was then carefully chipped away so that the top of the otic capsule could be visualized. The pinna was removed and the external ear canal was partially dissected away to allow positioning of the tip of a probe containing both a microphone and sound sources (ER10X, Etymotic Research) within a few mm of the tympanic membrane. The probe tip was glued to the rim of the dissected ear canal to create a closed sound field. After completing all desired vibration measurements, mice were killed by anesthetic overdose and a limited set of measurements was repeated postmortem.
Volumetric optical coherence tomography and vibrometry.
We used an optical coherence tomography-based approach [volumetric optical coherence tomography and vibrometry (VOCTV)] to noninvasively image through the cochlear bone and record vibratory responses from the apical cochlear turn, as described previously (Gao et al., 2014; Lee et al., 2015, 2016). Briefly, the custom-built system consisted of a broadband swept-source laser (MEMS-VCSEL, Thorlabs; center-wavelength = 1300 nm, bandwidth = 100 nm, sweep rate = 200 kHz), a dual-balanced photodetector (WL-BPD600MA, Wieserlabs), and a high-speed digitizer (NI-5761, National Instruments) connected to a desktop PC. An adaptor attached to the bottom of the dissecting microscope (Stemi-2000, Zeiss) housed a 2-D voice coil mirror that was used to scan the light source across the preparation to obtain cross-sectional images of the cochlear duct. After imaging the apical cochlear turn, vibratory responses were obtained from specific voxels on the BM and from the RL, near the top of the OHC region. Measurements were always obtained from local maxima in the reflectivity versus depth profile to increase the vibratory signal-to-noise ratio. The angle between the light source and the BM was ∼60–75°, such that the vibration measurements largely captured the transverse motions of the BM and RL.
The imaging resolution of our system was previously determined to be ∼9.8 and ∼11.4 μm (full-width at half-maximum) in the lateral and axial dimensions, respectively (Lee et al., 2015, 2016). Because the BM is ∼20 μm thick in the mouse cochlear apex (Keiler and Richter, 2001), our measurements of BM motion were likely dominated by the BM. However, because we cannot measure vibrations directly from the surface of the RL, our measurements of RL vibration probably reflect the combined motion of the RL and the upper half of the OHC region, over the width of at least one OHC. OHCs in the mouse cochlear apex are ∼20 μm in length, ∼5–7 μm in diameter, and spaced ∼8 μm apart (Zajic and Schacht, 1987; Soons et al., 2015). We did not systematically explore the vibratory properties of locations deeper within the organ of Corti, where the motions are likely more complex, with transverse, radial, and longitudinal components (Gao et al., 2014; Lee et al., 2016; Cooper et al., 2018). However, to the extent that the motion of these locations is influenced by OHC activity (Cooper et al., 2018), measurements of two-tone suppression at these locations would presumably be similar to what we measured at the RL.
Stimulus paradigms.
Sound stimuli were calibrated before each experiment using a Brüel & Kjær 1/8 inch microphone (Type 4138) coupled to the sound delivery probe via a ∼3 mm length of tubing to approximate the residual ear canal. At the beginning of an experiment, responses to 50–100 ms tones were obtained to determine the CF of the cochlear location being imaged. The CF was defined as the frequency at the peak of the BM response to a 30 dB sound pressure level (SPL) tone swept from 1 to 15 kHz in 0.5 kHz steps, and was either 9 kHz (n = 4) or 9.5 kHz (n = 6) in the 10 mice studied. The effects of different suppressor tones on the response to a near-CF probe tone (with frequency 0.1 kHz above the CF, thus either 9.1 or 9.6 kHz) or low-frequency probe tone (2.1–6.1 kHz) were then assessed. For each stimulus presentation, a probe tone was presented for 100 ms, and a suppressor tone was presented for 100 ms after the probe tone had been on for 50 ms. This yielded three 50 ms intervals containing the response to (1) the probe alone, (2) both the probe and suppressor tones, and (3) the suppressor alone. All responses were averaged across 4–8 stimulus presentations. The response to the probe and/or suppressor frequency components in each interval was then determined from a fast Fourier transform after applying a Hanning window to the time-domain signal. Suppression was defined as the amount (in dB) by which the probe response was reduced by the presence of the suppressor.
For each probe tone, suppression was examined as a function of the suppressor tone frequency (extending from the CF in 1 kHz steps over a range covering ∼1–20 kHz) and level (30–90 dB SPL in 5 dB steps). Suppression measurements were attempted for as many probe frequencies and levels as possible. However, the number of usable measurements from a given preparation was limited by the high measurement noise floors at low probe frequencies, and premature death resulting from the anesthesia. To facilitate comparisons across the same set of measurement conditions within a sufficient number of mice, we prioritized characterizing the suppression of BM and RL responses to near-CF probe tones and RL responses to 4.1 kHz probe tones, using a probe level of 60 dB SPL, before obtaining measurements at other probe frequencies and levels. For a stimulus level of 60 dB SPL, BM and RL responses to near-CF tones and RL responses to 4.1 kHz tones were similar in magnitude and had signal-to-noise ratios that were adequate for characterizing suppression. Suppression of BM responses to below-CF probe tones was not assessed, as there is little amplification of BM motion at these frequencies (Rhode, 2007; Versteegh and van der Heijden, 2013) and the vibratory amplitudes were too small to reliably characterize suppression.
Responses to single tones presented at 30 dB SPL were repeatedly assessed throughout each experiment to verify that the CF and sensitivity of the preparation did not change over time. Responses to single tones were also obtained after death so as to characterize the loss of OHC-mediated amplification postmortem. However, suppression measurements were not repeated after death, because of the loss of the nonlinearities associated with cochlear amplification, as well as the reduction of most probe responses into the measurement noise floor.
Data analysis.
For each probe frequency and level, the suppressor level required to reduce the probe response by a criterion amount (1.5–12 dB) was calculated for each suppressor frequency to produce a family of suppression threshold curves. Curves were parameterized so as to determine the frequency and threshold level at the minimum (or “tip”) of the curve, as well as the sharpness of tuning, which was assessed by dividing the tip frequency by the bandwidth 10 dB up from the tip, yielding the quality factor Q10 dB. Most importantly, we assessed the high-frequency extent of suppression by determining the highest suppressor frequency that produced a criterion amount of suppression when the suppressor was presented at 70 dB SPL. In other words, we calculated the 70 dB SPL intercept for each suppression threshold curve at frequencies above the CF. Using the frequency-to-place map of the mouse cochlea (Müller et al., 2005), we then calculated the distance between the measurement location and the tonotopic place of the highest effective suppressor frequency (defined as the 70 dB SPL suppression threshold intercept). This yielded an estimate of the longitudinal region over which OHCs contributed amplification to the probe response at our measurement location. In some cases, calculation of the 70 dB SPL intercept required that suppression thresholds be extrapolated to slightly higher frequencies. To average responses across preparations with different CFs, stimulus frequencies were converted to octave values relative to the CF, and the data from each mouse were interpolated in fixed 1/20th-octave steps. All vibratory data presented and analyzed in this report had magnitudes that were at least 3 SDs above the mean noise floor in frequency bins ± 200–300 Hz around the stimulus frequency. Response phases were corrected by subtracting the stimulus phase measured in the ear canal.
Experimental design and statistical analysis.
A within-subjects design was used to compare the vibratory characteristics of the BM and RL as well as the suppression of BM and RL responses to different probe frequencies and/or levels. Repeated-measures ANOVAs followed by post hoc pairwise comparisons with Bonferroni corrections were conducted using SPSS software to determine the statistical significance (at the p < 0.05 level) of differences in suppression threshold parameters across measurement conditions. The Greenhouse–Geisser correction was used to adjust the degrees of freedom of the F distribution in cases where the data violated the assumptions of sphericity. Paired, two-tailed t tests were used when only two quantities were obtained from the same mice and compared. One-sample t tests were also used to assess whether the tip frequencies of the suppression threshold curves were significantly different from the CF. For t tests and ANOVAs, we provide the t or F statistic along with the degrees of freedom in parentheses (for ANOVAs, both between-group and within-group degrees of freedom are reported), the p value, and the number of mice (n) included in each test. The number of mice used in each analysis varied because it was not possible to obtain suppression measurements for all probe frequencies and levels in every preparation. All reported values are the average ± SEM. When reported in the context of statistical comparisons across measurement conditions, averages only include data from mice in which all relevant measurement conditions were completed.
Results
BM and RL responses to single tones
We used VOCTV to noninvasively image through the cochlear bone (Fig. 2A,B) and record sound-evoked vibrations from the apical turn of the adult mouse cochlea (Gao et al., 2014; Lee et al., 2015, 2016). We first characterized the vibrations of the BM and RL in response to single tones and determined the CF of a given measurement location (Fig. 2C–F; CF = 9 kHz in this example). As described previously (Lee et al., 2016; Ren et al., 2016b), displacements of the BM and RL exhibited nonlinear, compressive growth with increasing stimulus level for stimulus frequencies near the CF, and more linear growth at lower frequencies. RL responses were generally larger and grew more compressively than BM responses, particularly at low frequencies. These differences are more evident after normalizing the displacements to the stimulus pressure (Fig. 2G,H), where the degree of nonlinearity is indicated by the separation between curves obtained at different stimulus levels. After death, the nonlinearity observed in BM and RL responses was eliminated, and low-frequency RL responses were dramatically reduced in magnitude. The vulnerability of low-frequency RL responses indicates that, at frequencies well below the CF, RL motion is actively amplified by OHCs. In contrast, BM motion is amplified very little at low frequencies. The mean live/dead displacement ratio for a 60 dB SPL 4 kHz tone was 4.04 ± 0.91 dB for the BM, and 23.82 ± 0.75 dB for the RL (significantly different by paired t test, t(9) = 21.55, p < 0.001, n = 10).
Although measurements from the base of the mouse cochlea have shown that the RL moves out of phase with the BM at low frequencies and in phase near the CF (Ren et al., 2016b), we observed the opposite phase relationship (Fig. 2I,J). BM and RL motion were nearly in phase at low frequencies, and RL motion progressively lagged BM motion as the stimulus frequency was increased (RL–BM phase for a 70 dB SPL, CF tone = −0.33 ± 0.04 cycles; t(8) = 8.59, p < 0.001, n = 9, paired t test). This phase difference was physiologically vulnerable and largely disappeared after death (Fig. 2J). The different RL–BM phase relationship observed in our measurements could possibly be attributed to the different measurement location and/or differences in measurement angle (Cooper et al., 2018).
Suppression of responses to near-CF and below-CF tones
We next examined how a second tone suppressed BM and RL responses to a primary tone (referred to as the “probe”) presented at a frequency near the CF of the measurement site. This allowed us to map the extent of the buildup region basal to the peaks of the BM and RL traveling waves. Near-CF probes had frequencies 0.1 kHz above the CF, and thus were either 9.1 or 9.6 kHz. Representative data are shown from an experiment in which responses to a 60 dB SPL 9.6 kHz probe were monitored while suppressor tones at different frequencies were varied in level (Fig. 3).
We found that BM and RL responses to near-CF probes were suppressed by a similar range of frequencies extending just above the CF (Fig. 3D,E). Suppressor tones with frequencies more than an octave above the CF (e.g., 20.5 kHz) produced little suppression (<1 dB) of either BM or RL responses, indicating that amplification at the BM or RL traveling-wave peak did not depend on OHC-generated forces from far basal regions. However, suppressor tones with frequencies slightly above the CF (e.g., 14.5 kHz) did reduce near-CF probe responses, suggesting that amplification built up from regions just basal to the measurement site. Suppression caused by a 14.5 kHz tone was small (<5 dB) and grew little with increasing suppressor level (<0.1 dB/dB). This is consistent with the notion that the wave evoked by the 14.5 kHz tone only partly overlapped with the buildup region and grew compressively with stimulus level near its peak. Near-CF suppressor tones (e.g., 9.5 kHz) were most effective at reducing the probe response (with suppression approaching ∼30 dB), whereas below-CF suppressors (e.g., 3.5 kHz) produced comparable reductions only at high suppressor levels (>70 dB SPL). These patterns can be attributed to the greater sensitivity and more compressive growth of responses to near-CF versus below-CF tones at the measurement site (Ruggero et al., 1992; Cooper, 1996; Rhode, 2007).
The above results suggest that amplification of the RL traveling-wave peak does not build up from far basal regions. We therefore next directly assessed the buildup of RL amplification basal to the peak by examining the suppression of RL responses to a 4.1 kHz probe tone. This below-CF tone elicited a wave that peaked apical to our measurement site, allowing us to study a more basal region of the RL traveling wave (Fig. 3C). In contrast to BM and RL responses to near-CF probes, we found that RL responses to the 4.1 kHz probe were only suppressed by tones that directly vibrated the measurement site (e.g., 3.5 and 9.5 kHz), and were not influenced by suppressor frequencies much higher than the CF (14.5 or 20.5 kHz; Fig. 3F). The amplification of RL responses to the 4.1 kHz probe therefore did not build up significantly from regions basal to our measurement site, confirming that the buildup of amplification is restricted to a region near the peak of the RL traveling wave.
Estimating the extent of the buildup regions for the BM and RL
To more precisely estimate the spatial extent of the buildup regions for BM and RL responses, we calculated the suppressor level required to reduce the probe response by a criterion amount for a wide range of suppressor frequencies (Fig. 3G–I). Suppression thresholds are shown for criteria of 1.5–12 dB, demonstrating the consistency of the patterns across criteria. For BM and RL responses to near-CF probes, small amounts of suppression were most effectively achieved with suppressor frequencies just above the CF and were observed at frequencies up to 17.5 kHz (0.88 octaves above the CF). Suppression was observed despite the fact that suppressor tones above ∼13 kHz did not elicit displacements above the noise floor at the measurement site (Fig. 3G,H,J,K, gray shaded regions). For RL responses to the 4.1 kHz probe, small amounts of suppression were most effectively produced by suppressor frequencies near the CF, and suppression was only observed if the suppressor tone produced a displacement at the measurement site (Fig. 3I,L). Amplification of BM and RL responses to near-CF tones therefore built up over some distance basal to the measurement site, whereas the RL response to a 4.1 kHz tone was amplified locally.
Averaged data (n = 8–10) confirmed the different high-frequency extents of suppression for near-CF and 4.1 kHz probes (Fig. 4). To quantitatively compare these extents, we determined the highest-frequency 70 dB SPL suppressor tone that could suppress each probe response by a criterion amount (Fig. 4D, arrow indicates the 70 dB SPL intercept for 1.5 dB of suppression). We found that BM and RL responses to near-CF probes were suppressed by a similar range of suppressor frequencies, though suppression of BM responses extended to slightly higher frequencies for a suppression criterion of 1.5 dB (Fig. 4D,F; Table 1). This suggests that BM responses depend more strongly than RL responses on amplification provided by locations basal to the measurement site. Importantly, both BM and RL responses to near-CF probes were suppressed by significantly higher frequencies than RL responses to the 4.1 kHz probe, indicating that near-CF responses depended more strongly on amplification from basal locations than did below-CF responses. To estimate the extent of the buildup region for near-CF and 4.1 kHz responses, we used the frequency-to-place map of the mouse cochlea (Müller et al., 2005) to determine the characteristic location of the 70 dB SPL intercept frequency, and then calculated its distance from the measurement site. We estimate that amplification built up over a region 0.95 ± 0.024 mm basal to the measurement site (∼18% of the mouse cochlear length, 5.13 mm; Müller et al., 2005) for BM responses to the near-CF probe (n = 8), 0.71 ± 0.042 mm (∼14% of cochlear length) for RL responses to the near-CF probe (n = 10), and 0.54 ± 0.025 mm (∼10% of cochlear length) for RL responses to the 4.1 kHz probe (n = 10).
Other characteristics of the suppression threshold curves indicate that suppression of RL responses to the 4.1 kHz probe was more strongly tuned to frequencies near the CF, and that these responses were amplified locally (for statistical comparisons, see Table 1). The most effective suppressor frequency (i.e., the frequency at the tip of the suppression threshold curves) for RL responses to the 4.1 kHz probe was lower than those for BM and RL responses to near-CF probes, though only statistically significantly so when compared with BM responses. When compared individually to the CF of the measurement location, suppression threshold tip frequencies were not significantly different from the CF for RL responses to the 4.1 kHz probe (t(9) = −1.00, p = 0.343, n = 10, one-sample t test), whereas they were significantly higher than the CF for both BM and RL responses to near-CF probes (BM: t(7) = 30.02, p < 0.001, n = 8; RL: t(9) = 3.93, p = 0.003, n = 10, one-sample t test). The suppression of RL responses to the 4.1 kHz probe was also more sharply tuned, as quantified by the quality factor, Q10 dB. Lastly, suppression of RL responses to the 4.1 kHz probe required significantly lower suppressor levels, particularly at frequencies near the CF. This may reflect that amplification of the 4.1 kHz response was strongly localized to the measurement site, rather than being distributed over a basal region. Alternatively, near-CF probes may exert more of a suppressive influence on the response to the suppressor tones, thus reducing their efficacy.
Amplification of near-CF responses builds up over a broader region at lower stimulus levels
We initially studied the suppression of responses to probe tones presented at 60 dB SPL, as BM and RL responses to near-CF tones and RL responses to 4.1 kHz tones were comparable in magnitude at this level (BM, near-CF: 8.24 ± 0.51 nm; RL, near-CF: 9.35 ± 0.59 nm, RL, 4.1 kHz: 7.41 ± 0.83 nm; no significant pairwise differences after repeated-measures ANOVA, F(2,14) = 4.29, p = 0.035, n = 8). However, because both the probe and suppressor tones contribute to the saturation of OHC mechanotransduction currents, the probe level may influence the observed suppression patterns (Rhode, 2007). Moreover, the spatial extent of the buildup region may depend on stimulus level. We therefore next confirmed that the differences in suppression patterns noted above were observed at lower probe levels.
As we decreased the probe level from 60 to 50 and then 40 dB SPL, the suppression of BM and RL responses to near-CF probes was observed at lower suppressor levels and higher suppressor frequencies (Fig. 5A,B). The probe level had a significant effect on the 70 dB SPL suppression threshold intercept (BM: F(2,8) = 35.99, p < 0.001, n = 5; RL: F(2,10) = 16.41, p < 0.001, n = 6, repeated-measures ANOVA), with the 70 dB SPL intercept frequency being significantly higher for a probe level of 40 dB SPL versus 60 dB SPL (BM: p = 0.007; RL: p = 0.003). Amplification of near-CF responses therefore built up over a broader basal region at lower probe levels. Using the 70 dB SPL intercepts of the suppression threshold curves (and suppression criterion = 1.5 dB), we estimate that the buildup region for 50 and 40 dB SPL probe responses extended 1.02 ± 0.029 mm (n = 7) and 1.23 ± 0.033 mm (n = 5) basal for the BM, and 1.03 ± 0.051 mm (n = 8) and 1.16 ± 0.038 mm (n = 6) basal for the RL.
In contrast, the suppression of RL responses to a 4.1 kHz probe did not change as the probe level was reduced from 60 to 50 dB SPL (Fig. 5C; comparison of 70 dB SPL intercepts: t(4) = 0.003, p = 0.998, n = 5, paired t test), with an estimated buildup region of 0.56 ± 0.052 mm at 50 dB SPL (n = 5; responses at 40 dB SPL were too low in amplitude to characterize suppression). Differences in the high-frequency extents of suppression for 4.1 kHz versus near-CF probes were therefore slightly larger for a probe level of 50 dB SPL (Fig. 5D) than for a probe level of 60 dB SPL (Fig. 4D). For both probe levels, suppression threshold curves for RL responses to a 4.1 kHz probe had lower-frequency 70 dB SPL intercepts and lower tip thresholds, and were more sharply tuned than those for BM or RL responses to near-CF probes (Table 1). Additionally, suppression patterns for BM and RL responses to near-CF tones became more similar at lower probe levels, suggesting that the BM and RL may, in fact, share a common buildup region (70 dB SPL intercepts were not significantly different at probe levels of either 50 or 40 dB SPL; Table 1).
The buildup region of the RL traveling wave gradually transitions into the region where amplification is local
Differences in the extent of the buildup regions for near-CF and 4.1 kHz tones indicate that RL motion distant from the traveling-wave peak is locally amplified. However, above-CF suppressors could still produce ∼1.5–3 dB of suppression of the 4.1 kHz response even when they evoked very little displacement of the BM or RL (Figs. 3L, 4E). These effects were likely driven by suppression of OHC activity at locations slightly basal, suggesting that our measurement site fell in a region where there was still some spatial buildup of amplification for the 4.1 kHz response. We therefore next examined whether the degree of buildup depended on the distance of our measurement site from the peak of the traveling wave, which we varied by changing the probe frequency.
We found that the suppression of RL responses to below-CF probe frequencies ranging from 2.1 to 6.1 kHz generally resembled that observed for the 4.1 kHz probe (Fig. 6A–E). However, with increasing probe frequency, above-CF suppressor tones became progressively more effective at reducing the response to the probe. This was evidenced by increases in the frequency of the 70 dB SPL suppression threshold intercept as the probe frequency was increased (Fig. 6E,F; F(3,12) = 7.48, p = 0.004, n = 5, repeated-measures ANOVA for probe frequencies between 2.1 and 5.1 kHz; 6.1 kHz probe data excluded because of low n). Above-CF suppressor tones were, in fact, as effective in reducing the response to a 6.1 kHz probe as they were for a near-CF probe (t(2) = 1.06, p = 0.401, n = 3, paired-samples t test). We estimate that the buildup region extended 0.76 ± 0.069 mm (n = 3) basal to the measurement site for the 6.1 kHz probe, but only 0.38 ± 0.033 mm (n = 5) for the 2.1 kHz probe. Thus, the degree to which the RL response accumulated gain from more basal regions depended on the proximity of our measurement site to the peak of the traveling wave. The region of the wave where amplification is primarily local (further from the peak) appears to smoothly transition into the region where amplification builds up significantly (closer to the peak; Fig. 6G). The buildup of amplification is therefore likely controlled by a property that varies continuously along the length of the cochlea, or that varies with position in the traveling-wave vibration pattern.
Discussion
It is well established that the BM traveling wave is selectively amplified near its peak and accumulates gain over the amplifying region (Fisher et al., 2012). Here we demonstrate that although the RL traveling wave is amplified throughout its basal extent, it too only accumulates gain near the wave's peak. Elsewhere, OHC-generated forces locally amplify RL motion without influencing RL (or BM) motion at neighboring locations. This contradicts the proposition that amplification of below-CF RL motion underlies a global mechanism for amplifying the traveling-wave peak (Ren et al., 2016b; He et al., 2018). Such a mechanism was proposed based on the observation of OHC-mediated, anti-phasic RL and BM motion at below-CF frequencies in the cochlear base of mouse and gerbil. This motion could theoretically pump fluid longitudinally along the organ of Corti to enhance the traveling wave as it propagates apically (Karavitaki and Mountain, 2007; Zagadou and Mountain, 2012). However, our measurements indicate that OHC activity in the base contributes little to the amplification of BM or RL traveling waves in the apex. Instead, our data reveal that a spatially-selective mechanism controls the buildup of amplification along both the bottom and top of the organ of Corti.
While the buildup of amplification is necessary to produce sensitive responses at the traveling-wave peak, restricting its spatial extent is also advantageous. Such restriction sharpens the wave's peak, thereby enhancing frequency selectivity, and ensures that cochlear sensitivity at each location depends on a limited population of nearby OHCs. This prevents high-frequency sounds from interfering with the amplification of low-frequency sounds, which likely aids in processing broadband signals such as speech and environmental sounds. Importantly, this restriction also minimizes the impact of OHC damage in one location on sensitivity elsewhere, such that OHC damage in the cochlear base has little effect on apical responses (Dallos and Harris, 1978; Cody, 1992).
Though the buildup region for near-CF tones appears to be slightly broader for the BM (∼0.95–1.23 mm) than the RL (∼0.71–1.16 mm), the buildup of amplification along the BM and RL is likely controlled by common mechanisms (as discussed below). The broader buildup region observed for the BM versus RL response to a 60 dB SPL probe can be explained by the fact that above-CF suppressors reduce the gain provided by basal locations without directly stimulating the measurement site, and thus effectively reduce the local probe level (Versteegh and van der Heijden, 2013). Because RL vibrations grow more compressively than BM vibrations with increasing level, reducing the local probe level has less of an effect on RL responses to moderate-level probes. Likewise, the broadening of the buildup region with decreasing probe level can be explained by the less compressive growth of near-CF BM and RL responses at lower stimulus levels. Reducing the local probe level therefore impacts a 40 dB SPL response more than a 60 dB SPL response. The buildup region's apparent extent thus partially reflects whether local amplification can compensate for the loss of amplification provided by basal locations.
Although we refer to the buildup region as being spatially restricted, 0.71–1.23 mm spans a considerable portion of the mouse's cochlear length (∼14–24% of 5.13 mm; Müller et al., 2005). Similar absolute extents of the buildup region can be estimated from BM suppression data in chinchilla (∼1.8 mm; Rhode, 2007) and gerbil (∼1.1–1.3 mm; Versteegh and van der Heijden, 2013), though these distances only span ∼9–10% of the cochlear length (∼20.1 and 11.1 mm in chinchilla and gerbil, respectively; Müller, 1996; Müller et al., 2010). Similar or slightly shorter buildup regions have been estimated from the effects of inactivating OHC motility on BM vibrations in chinchilla (>0.5 mm; Fisher et al., 2012) and the effects of acoustic trauma on auditory nerve fiber sensitivity in guinea pig (∼0.5–1.3 mm; Cody, 1992). Thus, although cochlear length may vary widely across species, the absolute longitudinal influence of OHC activity on cochlear vibrations appears to be relatively constant.
The amplification of below-CF RL motion indicates that OHCs are stimulated over a wide frequency range and provide wideband force generation in response (Frank et al., 1999; Ren et al., 2016a). Whereas the BM does not respond to these below-CF forces, the RL does, likely because it is directly attached to the apical surfaces of the OHCs and is less stiff than the BM (Mammano and Ashmore, 1993; Richter and Quesnel, 2006). However, whether these forces build up longitudinally depends on the degree of coupling between adjacent locations. Our findings indicate that direct coupling of OHC-generated forces along the RL is weak, because there was little spatial buildup of below-CF RL amplification. Instead, our data suggest that longitudinal coupling of OHC-generated forces may be largely mediated by the BM and its interactions with the cochlear fluids. This is because the buildup of RL amplification was only observed near the peak of the traveling wave, where OHC-generated forces are capable of influencing BM motion. If the BM's spatially-graded impedance underlies how OHCs selectively amplify BM motion near the peak of the traveling wave, then this property could also explain why longitudinal coupling is limited to this region.
However, the micromechanics of the organ of Corti are likely also involved in spatially restricting BM amplification and/or the longitudinal coupling of OHC-generated forces. For instance, maximal BM amplification occurs when OHC force generation is in phase with BM velocity, such that a frequency-dependence in the phase of the OHC stimulation (and, thus, force production) could produce selective BM amplification near the CF (Dong and Olson, 2013; Nankali et al., 2018). The Y-shaped geometry formed longitudinally by the OHCs and Deiters' cells has also been proposed to underlie the spatially-selective amplification and buildup of BM motion (Geisler and Sang, 1995; Yoon et al., 2011). A model that emphasizes the importance of this geometry has recently been extended to include the RL's mechanics and replicates some of the differences in RL and BM motion (Motallebzadeh et al., 2018). The similarity in the buildup region's extent across species supports the idea that longitudinal coupling of OHC-generated forces depends on the cellular dimensions and geometry within the organ of Corti, which are also similar across species (Yoon et al., 2011).
Additionally, although longitudinal coupling along the apical surface of the organ of Corti is apparently weak below the CF, it is possible that this coupling is enhanced near the CF. For instance, the tectorial membrane (TM) and its interactions with OHC stereocilia have been shown to confer longitudinal coupling to the cochlear partition and increase near-CF responses (Russell et al., 2007; Dewey et al., 2018). This coupling likely involves longitudinally-propagating waves of radial motion on the TM (Ghaffari et al., 2007; Sellon et al., 2015). Because the micromechanics of the organ of Corti enhance radial RL motion near the CF (Lee et al., 2016), the interplay between radial RL and TM motion could facilitate longitudinal coupling of OHC-generated forces at these frequencies. Longitudinal electrical coupling between OHCs (Ramamoorthy et al., 2007) could also be frequency dependent.
The functional role of amplifying below-CF RL motion remains uncertain. Nevertheless, this motion must shape how the OHCs and IHCs are stimulated, because their stereocilia protrude from the RL. As evidence for this, below-CF auditory nerve fiber responses can be inhibited by tones (Nam and Guinan, 2018) and by stimulation of the medial olivocochlear efferents (Stankovic and Guinan, 1999, 2000), which innervate OHCs. This suggests that IHCs are excited by the amplified, below-CF RL motion. However, IHC receptor potentials are relatively insensitive to below-CF tones (Russell et al., 1986) compared with RL vibrations, and auditory nerve fiber tuning more closely resembles the BM's mechanical tuning in the cochlear base (Narayan et al., 1998). The influence of below-CF RL motion may therefore be filtered out of the mechanical drive to the IHC stereocilia or by the mechanotransduction process. Sensitivity to velocity, rather than displacement, (Robles and Ruggero, 2001) or fast adaptation of mechanotransduction currents (Kennedy et al., 2003; Ricci et al., 2005) could provide this high-pass filtering.
OHCs are more sensitive than IHCs to below-CF tones (Russell et al., 1986; Kössl and Russell, 1992), perhaps reflecting a greater influence of RL motion. Additionally, the suppression of below-CF RL motion may have correlates in the suppression of other OHC-dependent responses, such as the cochlear microphonic (Legouix et al., 1973; Cheatham and Dallos, 1982) and otoacoustic emissions (Martin et al., 1999; Charaziak and Siegel, 2015), by tones presented several octaves above the stimulus frequency. Nevertheless, the semitransverse RL displacements reported here are likely a poor estimate of the stimulus to the OHC stereocilia, which are deflected by radial shear between the RL and TM. Future studies of 3-D cochlear micromechanics are needed to fully understand how RL motion influences the radial stimulation of hair cells, and thus the auditory nerve. Here we show that the influence of transverse RL motion along the longitudinal direction is spatially restricted by mechanisms that likely derive from the mechanical properties of the BM and organ of Corti.