Table 3.

Cellular properties of VH neurons before and during exposure to Cort

ParameterControl (n = 6)Treated (n = 12)p value
RMP (mV)−57.33 ± 0.66−57.67 ± 0.550.721
Input resistance (MΩ)42.05 ± 1.0340.86 ± 1.140.068
τ (ms)26.36 ± 0.9423.12 ± 1.060.057
AP threshold (mV)−35.85 ± 0.57−42.66 ± 0.91<0.001
AP amplitude (mV)112.1 ± 1.29113.17 ± 1.740.146
AP duration (ms)3.35 ± 0.1433.90 ± 0.1400.077
AP time to peak (ms)0.116 ± 0.0090.095 ± 0.0040.052