Table 5.

Parameters for the default, bat, rat, mouse, and frog DTN models

DTN model parametersDefaultBataRatbMouseFrog
Onset excitatory input latency (re stimulus onset) (ms)1012151438
Offset excitatory input latency (re stimulus offset) (ms)614326None
Inhibitory input latency (re stimulus onset) (ms)91215/501229
AMPA (nS)41231.91.19
NMDA (nS)208121936
GABAA (nS)2.583/0.81.20.32
Membrane τ (ms)41.21059
  • aExcitatory input removed for 1 ms stimuli.

  • bShort-latency, strong inhibition lasting up to 35 ms; weak inhibition sustained for stimulus duration.