Table 1.

Overview of stimulation protocols

Stimulus protocolBinaural vs monauralBinaural correlationNoise typeSound level/ABIILDStimulus duration
ILD tuning curveBinaural100%UnfrozenConstant (40 dB)−40 to 40 dB100 ms
ILDfBinaural100%UnfrozenVaryingVarying100 ms
Monaural intensityMonauralN/AUnfrozen10 dB to 80 dBN/A100 ms
STRF estimationBinaural    0%UnfrozenConstant (40 dB)2 ILDs over dynamic range500 ms
Response reliability, ILD protocolBinaural100%FrozenConstant (40 dB)2–3 ILDs over dynamic range500 ms
Response reliability, ILDf protocolBinaural100%FrozenVaryingVarying500 ms
Response reliability, monaural excitation protocolMonauralN/AFrozen2–3 dBs in dynamic rangeN/A500 ms
  • N/A, Not applicable.