Table 4.

Amplification of oscillatory power in each circuit node when stimulus is applied to GPe or striatuma

Applied to GPeApplied to striatum
8 Hz25 Hz60 Hz8 Hz25 Hz60 Hz
Stimulus power amplification (DD-control)
    GPe0.04 ± 0.15*2.87 ± 0.30*−0.09 ± 0.12*0.11 ± 0.06d2.25 ± 0.48d,e0.13 ± 0.30e
    FSI−0.07 ± 0.06b,c0.44 ± 0.06b0.45 ± 0.18c0.15 ± 0.06f0.17 ± 0.12g1.94 ± 0.99f,g
    MSN−0.07 ± 0.15*1.78 ± 0.21*0.31 ± 0.06*−0.14 ± 0.06*2.31 ± 0.39*0.99 ± 0.36*
  • aDifferences in amplification (DD stimulus bandpower − Control stimulus bandpower) of oscillatory stimulus. Power amplification in units of 1 × 109 V2/Hz. Values are mean ± SD.

  • b,c,d,e,f,gLetters indicate a significant difference between just two values (at least p < 0.05). Pairwise comparisons were only computed following a significant one-way ANOVA.

  • *Pairwise comparisons between all three conditions were significantly different (at least p < 0.05).