Abstract
According to Einstein’s equivalence principle, inertial accelerations during translational motion are physically indistinguishable from gravitational accelerations experienced during tilting movements. Nevertheless, despite ambiguous sensory representation of motion in primary otolith afferents, primate oculomotor responses are appropriately compensatory for the correct translational component of the head movement. The neural computational strategies used by the brain to discriminate the two and to reliably detect translational motion were investigated in the primate vestibulo-ocular system. The experimental protocols consisted of either lateral translations, roll tilts, or combined translation–tilt paradigms. Results using both steady-state sinusoidal and transient motion profiles in darkness or near target viewing demonstrated that semicircular canal signals are necessary sensory cues for the discrimination between different sources of linear acceleration. When the semicircular canals were inactivated, horizontal eye movements (appropriate for translational motion) could no longer be correlated with head translation. Instead, translational eye movements totally reflected the erroneous primary otolith afferent signals and were correlated with the resultant acceleration, regardless of whether it resulted from translation or tilt. Therefore, at least for frequencies in which the vestibulo-ocular reflex is important for gaze stabilization (>0.1 Hz), the oculomotor system discriminates between head translation and tilt primarily by sensory integration mechanisms rather than frequency segregation of otolith afferent information. Nonlinear neural computational schemes are proposed in which not only linear acceleration information from the otolith receptors but also angular velocity signals from the semicircular canals are simultaneously used by the brain to correctly estimate the source of linear acceleration and to elicit appropriate oculomotor responses.
In everyday life, one often experiences movements that involve both rotational and translational components. In addition, most naturally occurring rotational movements are accompanied by a concurrent change in head orientation relative to gravity. Running and locomoting, for example, have been shown to be characterized by high-frequency rotational and translational motion components (Grossman et al., 1988; Pozzo et al., 1990). Motion information is transduced by the vestibular system, which consists of separate receptors that respond to either angular (semicircular canals) or linear (otolith organs) accelerations. Because tilt and translation induce inertial accelerations of the otoconia that are physically equivalent (Einstein’s equivalence principle; Einstein, 1908), primary otolith afferent neurons provide equivalent responses to both head tilts relative to gravity and to translational movements (Loe et al., 1973; Fernandez and Goldberg, 1976; Anderson et al., 1978; Dickman et al., 1991; Si et al., 1997). Thus, the otolith signals transmitted to the CNS merely encode the resultant linear acceleration (α), which is equal to the vectorial sum of the translational (f) and gravitational (g) components, i.e., α = f +g.
Despite indiscriminate primary otolith afferent information, motor responses to head tilts and translations must be different. With respect to the oculomotor system, for example, a roll tilt of the head toward the shoulder should elicit ocular torsion, whereas a lateral head translation should generate horizontal eye movements (Bronstein and Gresty, 1988; Crawford and Vilis, 1991; Paige and Tomko, 1991a;Schwarz and Miles, 1991; Haslwanter et al., 1992; Tweed et al., 1994;Angelaki and Hess, 1996b; Telford et al., 1997; Angelaki, 1998). Because otolith afferent information does not discriminate between different sources of linear acceleration, it becomes the task of the CNS to correctly differentiate the acceleration source and to elicit functionally compensatory motor responses.
Two hypotheses have been proposed as to how the brain might solve the tilt–translation ambiguity of otolithic receptor information. According to the “multisensory integration” hypothesis, the brain must combine information from different sensors, such as the vestibular rotation sensors (i.e., the semicircular canals) and the otolith organs, to correctly differentiate between head translation and tilt (Guedry, 1974; Mayne, 1974; Young, 1974). Alternatively, the “frequency-segregation” hypothesis states that the frequency content of the otolith signals determines the source of acceleration. Accordingly, high-frequency accelerations are interpreted as translations, whereas low-frequency accelerations are interpreted as tilts (Paige and Tomko, 1991a; Telford et al., 1997).
In the present study, predictions derived from these hypotheses were tested. To directly investigate whether information from the semicircular canals is used by the CNS to correctly interpret linear accelerations, the horizontal eye movements elicited by linear acceleration before and after canal inactivation were taken as a measure of the capacity of the brain to encode head translation. The results refute frequency segregation as the primary computational scheme used to discern movement. Rather, functional semicircular canal signals are critical for an appropriate discrimination of the source of linear acceleration and the mode of head motion.
MATERIALS AND METHODS
Animal preparation and eye movement recording
Binocular three-dimensional (3-D) eye movements were recorded using the magnetic search coil technique. The driver coils, which generated horizontal and vertical magnetic fields (100 and 66 kHz, respectively) were mounted on a cubic fiberglass frame of 16-inch side length (CNC Engineering). Five rhesus monkeys (Macaca mulatta) were implanted with a head-restraining platform and dual search coils on each eye under gas anesthesia. Details for the surgical procedures have been described elsewhere (Angelaki, 1998). All surgeries were performed under sterile conditions in accordance with the Institutional Animal Care and Use Committee and National Institutes of Health guidelines. Anesthesia was initiated with an intramuscular injection of ketamine (10 mg/kg), followed by administration of an inhalative anesthesia that consisted of an O2–isoflurane mixture. Respiration, body temperature, and heart rate were continuously monitored. Animals were given antibiotics and analgesics after completion of each surgery. In addition, the lumens of all six semicircular canals were plugged in two of the animals, as described previously (Ewald, 1892; Angelaki et al., 1996). Canal-plugged animals showed no evidence of spontaneous nystagmus other than the normal downbeat nystagmus that is observed also in intact animals in darkness. After the surgery, animals were kept in complete darkness until the next morning when they were brought to the laboratory for vestibular testing (“acute” experimental protocol). After this acute vestibulo-ocular reflex (VOR) testing, animals were returned to the regular diurnal cycle.
The dual eye coil assembly that was implanted on each eye consisted of two serially interconnected miniature coils (Sokymat, Veveyse Switzerland) that were attached at diagonal points along the circumference of an ∼15 mm three-turn stainless steel coil (Cooner wire). The exact orientation of the two coils relative to each other and the orientation of the dual eye coil on the eye were precisely determined based on both preimplantation and daily calibration procedures (Hess 1990; Hess et al., 1992). Briefly, each dual eye coil was calibrated before surgical implantation with a 3-D calibration jig. Using rotations about all three axes, this calibration yielded the coil sensitivities, as well as the angle between the two coil sensitivity vectors. In each experimental session and protocol, pretrained animals performed a visual fixation task. The eye coil voltages measured during visual fixation, along with the precalibrated values for the sensitivity vector of the torsion coil and the angle between the two coils, were used to calculate the orientation of the dual coil on the eye, as well as offset voltages.
3-D eye positions were expressed as rotation vectors using straight-ahead gaze as the reference position. Angular eye velocity was computed from these rotation vectors (cf. Angelaki and Hess, 1996a,b,c). Both eye position and angular eye velocity vectors were expressed relative to a head-fixed right-handed coordinate system, with the head placed in an 18° nose-down position (see below). Torsional, vertical, and horizontal eye position and velocity were defined as the components of the eye position and eye velocity vectors along the naso-occipital, interaural (IA), and vertical head axes, respectively. Positive directions were clockwise (as viewed from the animal, i.e., rotation of the upper pole of the eye toward the right ear), downward, and leftward for the torsional, vertical, and horizontal components, respectively.
Experimental setup and protocols
During experimental testing, the monkeys were seated in a primate chair, with their heads statically positioned such that the horizontal stereotaxic plane was tilted 18° nose-down. This head position was used to place the lateral semicircular canals approximately parallel to the earth-horizontal plane, while at the same time keeping the vertical semicircular canals as vertically oriented as possible. The animal’s body was secured with shoulder and lap belts, while the extremities were loosely tied to the chair. The primate chair was then secured inside the inner frame of a vestibular turntable, which consisted of a 3-D rotator on top of a linear sled powered by a servo-controlled linear motor (2 m length; Acutronics Inc.). The two inner frames of the turntable were manufactured by nonmetallic composite materials to minimize interference with the magnetic fields. The 3-D turntable was used to deliver roll movements, whereas the linear sled was used to laterally translate the animals.
Experimental protocol 1. Steady-state sinusoidal oscillations at 0.16, 0.5, and 1 Hz were delivered in complete darkness (vergence angle of ∼1 MA) (Angelaki, 1998). For each of these frequencies, four stimulus combinations of lateral translation and/or roll tilt were tested. The peak amplitudes during combined tilt–translational motion profiles are provided in Table 1A. As shown in Figure 1Afor 0.5 Hz stimuli, the Translation only stimulus consisted of translational displacements (±36.7 cm) along the animal’s IA axis, with a peak IA shear acceleration of 0.37G). In Figure1B, the Roll tilt only stimulus consisted of earth-horizontal axis roll oscillations (±21.8°), which generated the same IA shear acceleration of 0.37G). In Figure 1C, theRoll tilt + Translation stimulus consisted of lateral linear translations (sled motion, ±39.8 cm) combined with simultaneous roll tilt oscillations (±21.8°). The translational and tilt motions were produced in phase such that a total IA acceleration of 0.74G resulted. The Roll tilt − Translation stimulus in Figure1D consisted of the same combined translation and tilt components, except that the two motions were out of phase. This produced a total IA acceleration of 0.0G.
Because the roll movements were nested inside the translational displacement, the translational acceleration along the IA axis differed slightly from that delivered by the linear sled. Specifically, if the roll oscillation amplitude is described by the equation θ(t) = θo · sin(ωt), and the translational acceleration during linear motion is described by the equation ƒtr = ƒo · sin(ωt + γ), where γ is the relative phase between the two stimuli, then during a combined motion profile, the translational component of the acceleration along the IA axis (fy) and the vertical head axis (fz) would be: Equation 1a Equation 1bComponent ƒy modulates sinusoidally at frequency ω, whereas component ƒz modulates at the second harmonic (2ω). Vertical slow phase velocity modulation was indeed seen in the responses of intact animals (see Fig. 2). These vertical slow phase eye velocity components were partly attributable to a misalignment of the roll VOR and partly attributable to a second harmonic contribution because of the changing head orientation relative to the translational displacement (i.e.,ƒz in Eqs. 1a,b). No such vertical eye movement components were elicited during combined tilt–translation in canal-plugged animals (see Fig. 5).
The total IA acceleration that results from simultaneous roll tilt and translation is given by the equation: Equation 2Equations 1 and 2 have been used here to compute the translational and resultant acceleration components along the IA axis (see Fig. 9).
Experimental protocol 2. In addition to the four sinusoidal protocols described above and illustrated in Figure 1, a more extensive tilt–translation combination battery of tests consisting of 0.5 Hz oscillations were also delivered (Table 1B). Specifically, (1) peak sled oscillation amplitude was kept constant (0.40G), whereas peak roll oscillation amplitude varied between 0° and ±21.8°; (2) peak sled oscillation amplitude was varied (0–0.40G), whereas peak roll oscillation amplitude was kept constant (21.8°); and finally, (3) the relative phase between the sled oscillations (0.4G) and roll oscillations (±21.8°) was varied in 45° steps. A phase of 0° corresponded to the Roll tilt + Translation motion condition, whereas a phase of 180° corresponded to the Roll tilt − Translation motion condition.
Experimental protocol 3. The same four main protocols (i.e.,Translation only, Roll tilt only, Roll tilt + Translation motion, and Roll tilt − Translation motion) were also tested with transient motion profiles. For these stimuli, the angular component of the stimulus consisted of a 15° roll tilt (angular velocity, 60°/sec; angular acceleration, 220°/sec2). The parameters of head translation were adjusted such that the inertial linear acceleration profile generated during translation closely matched that induced by the head tilt for the whole stimulus duration (∼500 msec). As a result, the Roll tilt − Translation transients exhibited nearly zero IA acceleration.
Experimental protocol 4. For comparison, earth-horizontal and earth-vertical axis roll oscillations were also delivered in a broader amplitude and frequency range. Specifically, the roll oscillation protocols in labyrinthine-intact animals included the following: ±5° (1 Hz); ±22° (0.5, 0.2, and 0.1 Hz); and ±90° (0.2, 0.1, 0.05, 0.02, and 0.01 Hz). Canal-plugged animals were only tested with the low-amplitude stimuli (5° and 22°).
All steady-state sinusoidal recordings were made in complete darkness. Under these conditions, vergence averages were ∼1 MA (Angelaki, 1998). Responses to transient stimuli were also recorded in complete darkness, but binocular fixation was controlled, and large vergence angles were obtained by initializing each trial only when the animal had satisfactorily fixated a target light located approximately in between the two eyes at a distance of 20 cm. The target light was extinguished immediately before the onset of motion and remained off until the animal came to a complete stop. All animals participating in these experiments were pretrained using juice rewards to fixate targets paired with an auditory cue for variable time periods (300–1000 msec) and then to maintain fixation after the target was turned off, for as long as the auditory tone was present (at least 1–2 sec). During all fixations, the room was illuminated (through small red lights) such that the animals could easily establish relative distance estimates of the targets. Adequate fixation was defined when both eyes were within behavioral windows (separate for each eye) of ±1.0°. Animals were trained to perform these fixation tasks for at least 1 month before any experimental testing. As shown by the eye position traces of Figure 10, animals quickly learned to maintain vergence in complete darkness for a minimum of 500 msec, as long as the auditory tone remained on.
Responses were first obtained in animals with intact labyrinths. As stated above, acute responses were obtained during the first day after canal plugging (see Figs. 5, 10). Data were recorded up to 3 months after plugging. Because no changes were observed in the horizontal translational VOR properties after canal plugging (Angelaki, 1998, Fig.7), data obtained at different times after plugging were included in the average (see Figs. 4, 6-9). The adequacy of canal plugging was physiologically verified by the lack of any response during earth-vertical axis yaw, pitch, and roll oscillations (0.1–1 Hz). These responses were systematically tested throughout the 3 month period of testing.
Data analysis
All data analyses were performed on personal computers off-line. First, calibrated 3-D eye positions were expressed as rotation vectors. The horizontal, vertical, and torsional components of the calibrated eye position vectors were then smoothened and differentiated with a Savitzky–Golay quadratic polynomial filter using a 15-point forward and backward window (Savitzky and Golay, 1964; Press et al., 1988). The angular eye velocity vector was computed from 3-D eye position and its derivative, as described previously (cf. Angelaki and Hess, 1996a,b,c). For transient motion profiles, only runs without fast phases for the first 500 msec were further analyzed. For sinusoidal stimuli, fast eye movements were removed from the eye velocity profiles using a semi-automated procedure based on time and amplitude windows set for the second derivative of the magnitude of eye velocity. Subsequently, average response cycles were computed from steady-state response components (i.e., horizontal, vertical, and torsional) for each eye. For each of these average response cycles, peak response amplitude and phase were determined by fitting a sine function (including first and second harmonic, as well as a direct current offset) to both slow phase eye velocity and stimulus (angular or linear velocity) using a nonlinear least squares algorithm based on the Levenberg–Marquardt method. Phase was expressed as the difference (in degrees) between peak eye velocity and peak angular velocity (for roll tilt and tilt–translation combination profiles) or linear velocity (for pure translational motion).
The results presented here concentrate on horizontal eye movements, because they reflect the coding of head translation. In contrast, torsional eye movements were considered inappropriate in this regard, because they are primarily generated by semicircular canal activation, whereas static or otolith-induced eye torsion is known to have small gain in primates and humans (Diamond et al., 1979; Paige and Tomko, 1991a; Haslwanter et al., 1992; Angelaki, 1998).
Statistical comparisons on the data were based on ANOVA.
RESULTS
Tilt–translation discrimination in labyrinthine-intact animals
In all animals with intact labyrinths, the elicited eye movements were compensatory for all stimulus combinations. As shown in Figure2, for example, sinusoidal lateral translation (Translation only), but not roll tilt oscillations (Roll tilt only), elicited robust horizontal eye movements in complete darkness. Moreover, during the combinedRoll tilt + Translation and Roll tilt − Translation motion profiles, the elicited horizontal eye movements were similar to those generated during Translation onlymotion. Thus, the horizontal eye movements generated in labyrinthine-intact animals totally ignored the linear accelerations caused by changes in head orientation relative to gravity during the roll movement. In fact, for all stimulus conditions (Translation only, Roll tilt only, Roll tilt + Translation, and Roll tilt − Translation motion protocols), the direction and magnitude of the horizontal response remained compensatory to the translational component of linear acceleration and was related neither to the acceleration produced by the roll tilt nor to the resultant IA acceleration. This was particularly striking for the Roll tilt − Translationprotocols in which robust horizontal eye movements were generated, despite the fact that the resultant IA acceleration was zero.
As reported previously (Tweed et al., 1994; Angelaki and Hess, 1996b), a small horizontal eye velocity modulation was often present during roll head movements. This has been further quantified in Figure3 in which sensitivity and phase of horizontal eye velocity during earth-horizontal and earth-vertical axis roll oscillations (filled and open symbols, respectively) are compared with those generated during lateral translation (triangles) (Angelaki, 1998, Fig.6). The horizontal eye movements elicited during both earth-horizontal and earth-vertical roll oscillations (i.e., rotations with the animals supine) were significantly smaller than those elicited during lateral head translation at the same frequency.
The observation that horizontal eye movements appropriately discriminated for tilt and translation is further illustrated in Figure4. In the frequency range tested, the results were independent of stimulus frequency (0.16, 0.5, and 1 Hz;F(4,23) = 0.81; p > 0.05). Accordingly, robust horizontal eye movements were generated only in the presence of translational motion (Fig. 4, Tran only,Roll+Tran, Roll−Tran). In contrast, the horizontal eye movement components elicited during Roll onlymotion were significantly smaller in amplitude than those generated during Translation only motion (F(1,15) = 68.0; p < 0.05). During the combined Roll tilt + Translation and Roll tilt − Translation motion profiles, the horizontal eye movements were indistinguishable from those generated duringTranslation only motion (F(2,23) = 2.1; p > 0.05). In fact, their amplitude and phase were always appropriate for gaze compensation during head translation.
Tilt–translation discrimination in canal-plugged animals
As shown in Figures 5 and6, results were different in canal-inactivated animals. Figure 5 illustrates responses from an animal acutely after canal plugging. Data from both canal-plugged animals have been summarized for all tested frequencies in Figure 6, A and B, respectively. Responses to two stimuli were of particular interest. First, during Roll tilt only stimulation, a robust horizontal response component was observed in canal-plugged, but not labyrinthine-intact, animals. In fact, the horizontal responses in canal-plugged animals were indistinguishable during Translation only and Roll tilt only motions (F(1,22) = 3.78;p > 0.05). Second, horizontal responses differed for each of the Translation only, Roll tilt + Translation, and Roll tilt − Translation motion profiles (F(2,32) = 115.5; p ≪ 0.05). Most noticeably, in the Roll tilt − Translation stimulus condition, horizontal slow phase velocity was negligible, as was the resultant IA acceleration (Fig. 5).
Different tilt–translation combinations
To further corroborate these results, the tilt–translation combination protocols were expanded at 0.5 Hz in two different ways (Table 1B). First, peak roll oscillation amplitude was kept constant (21.8°, corresponding to a peak gravitational acceleration component of 0.37G along the IA axis), whereas peak sled oscillation amplitude varied. Second, peak sled oscillation amplitude was kept constant (0.4G), whereas peak roll oscillation amplitude varied. In both sets of protocols, the resultant IA acceleration was identical, because it varied between 0 and 0.74G (in steps of 0.09G). Data from all three labyrinthine-intact and the two canal-plugged animals tested have been summarized in Figures7 and 8,A and B in both figures, respectively. As peak translational acceleration increased, peak horizontal eye velocity in labyrinthine-intact animals also increased in a linear manner, such that it was zero when fIA,peak was 0G (and IA acceleration was 0.37G) and maximal (minimal) whenfIA,peak was ±0.37G (Fig. 7A). In contrast, as the peak gravitational acceleration component along the IA axis was changed and as long as translational acceleration remained the same, horizontal eye velocity in labyrinthine-intact animals remained constant and independent of peak roll oscillation amplitude (Fig.8A). These data clearly demonstrate that the horizontal eye movements elicited during any combination of roll tilt and translation in labyrinthine-intact primates precisely follows the translational rather than either the resultant or gravitational component of acceleration.
Very different observations were made in canal-plugged animals. As illustrated when Figures 7B and 8B are compared, horizontal eye velocity exhibited the same dependencies on linear acceleration, independently of the nature of the stimulus. In both combination protocols, horizontal eye velocity was zero only when the resultant IA acceleration was zero. Furthermore, the practically indistinguishable behavior of horizontal eye velocity in Figures7B and 8B suggests that horizontal eye movements in canal-plugged animals are elicited in response to the resultant IA acceleration, with no functional distinction between tilt and translation. There was a nonlinear dependence of horizontal eye velocity on acceleration, exhibiting saturating characteristics at high IA acceleration levels. Horizontal eye velocity responses generated during pure translation (peak acceleration of 0.37G) have been superimposed in Figure 7B (open symbols). These data points fall approximately on the second order regression line drawn through the combination responses.
In a third protocol, the phase (γ) of the translation relative to the roll tilt was varied. As shown in Figure9B, amplitude and phase of horizontal eye velocity as a function of γ was predicted to differ, depending on whether the relevant stimulus was translational acceleration (f) or resultant IA acceleration (Eqs. 1, 2). Comparison of the observed peak horizontal eye velocity amplitude and phase as a function of the relative phase between tilt and translation strongly suggests different encoding of linear acceleration in intact and canal-plugged animals. When semicircular canals were intact and functional, the peak horizontal eye velocity depended on relative phase according to a relationship that resembled the translational acceleration dependence. In contrast, horizontal eye velocity was clearly characterized by IA acceleration-dependent behavior when the semicircular canals were inactivated (Fig.9A).
Transient tilt–translation stimuli
These observations regarding the role of semicircular canals in the correct discrimination of translational motion were independent of vergence angle. In fact, responses to transient head translation–roll tilt stimuli delivered as the animals maintained large vergence angles further corroborated these findings. Figure10 plots binocular horizontal eye position and velocity recorded during transient motion profiles that were delivered immediately after fixation on a near, central visual target located 20 cm from the eyes (vergence of ∼10°). The stimulus consisted of a quick roll tilt toward the right ear combined with a transient lateral displacement to the right, which was associated with a nearly zero acceleration along the IA axis (Roll tilt − Translation condition) (Fig. 10). The elicited horizontal eye movements before and after semicircular canal inactivation clearly differed. Whereas robust leftward horizontal responses were elicited in the intact animal, negligible horizontal eye movements were observed in the same animal after all semicircular canals had been inactivated.
DISCUSSION
The problem of sensorimotor discrimination between inertial (translational) and gravitational components of linear acceleration has been a long-debated issue in motor control and inertial navigation. This study shows that not only otolith but also semicircular canal signals are necessary sensory cues for the appropriate discrimination between different sources of linear acceleration. Therefore, the oculomotor system discriminates between head translation and tilt primarily by sensory integration rather than frequency segregation of otolith afferent information.
The central vestibular system correctly detects translational motion
Because of the inherent ambiguity associated with afferent coding of linear acceleration, it has often been implied that the oculomotor system (and motor systems in general) is bound by similar limitations. Based on responses obtained during translational oscillations between 0.5 and 4 Hz, for example, Paige and Tomko (1991a)and Telford et al. (1997) proposed that horizontal and torsional responses are always elicited simultaneously during both translation and tilt, as if responding to the resultant acceleration. Accordingly, otolith response ambiguity can only partially be resolved through central parsing of linear accelerations on the basis of frequency content. However, a direct test of this proposal was never performed.
Our results provide strong evidence in contrast to this interpretation, at least for the frequency range important for VOR compensation during movement (i.e., >0.1 Hz) (Angelaki, 1998). For all tilt–translation combination protocols, the direction and magnitude of the horizontal response of intact animals remained compensatory to the translational component of linear acceleration and was related neither to the acceleration produced by the roll tilt nor to the resultant IA acceleration. This was particularly striking for the Roll tilt − Translation protocols in which the resultant IA acceleration was zero, yet robust horizontal eye movements were generated.
Inactivation of semicircular canals compromises accurate detection of translational motion
The multisensory integration hypothesis predicts that both semicircular canal and otolith signals are needed for appropriate detection of the translational component of motion. In the absence of functional semicircular canal signals, correct motion discrimination would be compromised by interpreting the resultant IA acceleration as the translational stimulus. Conversely, if otolith signals were simply filtered, as the frequency-segregation hypothesis predicts, elimination of semicircular canal signals should have no effect on the ability of the vestibulo-ocular system to detect head translation.
The results from animals with inactivated semicircular canals clearly demonstrated that accurate discrimination between the translational and tilt components of motion was no longer possible. In fact, the elicited horizontal eye movements were always proportional to the resultant IA acceleration. The need for functional semicircular canal signals in the central processing of linear accelerations was further demonstrated by the experiments in which the relative phase of the two stimuli and either the translational or the gravitational component of acceleration was varied separately (Figs. 7-9). Noticeably, a nonlinear dependence of horizontal eye velocity on IA acceleration amplitude was observed in the plugged animals (Figs. 7B,8B). A similar amplitude nonlinearity has been described in primary otolith afferents above ∼0.4–0.5G (Fernández and Goldberg, 1976). Interestingly, no such amplitude nonlinearity was seen in animals with intact labyrinths (Fig.7A), although it is possible that primary afferents may have been driven into saturation.
Because translational VOR sensitivity strongly depends on viewing distance (Paige and Tomko, 1991b; Schwarz and Miles, 1991; Telford et al., 1997), the main stimulus combinations were also tested during short-lasting transient motion, immediately after satisfactory fixation on a near, centered target. The differences in the horizontal eye movements between labyrinthine-intact and canal-plugged primates were even more provocative when viewing distance was controlled (Fig. 10). Despite robust horizontal eye movements during the Roll tilt − Translation motion profile during near target fixation in labyrinthine-intact animals, no horizontal translational response was generated in canal-inactivated animals when the resultant linear acceleration along the IA axis was zero. These results demonstrate that in the absence of functional signals from the semicircular canals and with all other sensory inputs essentially unchanged before and after canal inactivation, any linear acceleration component along the IA axis will be centrally interpreted as translational motion and generate a horizontal (translational) VOR.
Nonlinear processing of vestibular afferent signals: neural computations to resolve tilt–translation ambiguity
A fundamental question that arises from these results relates to the computational mechanisms used by the brain to discriminate the source of linear acceleration and to correctly detect head translation. Semicircular canal signals could contribute to the discrimination of head motion according to either one of the following principles. First, central integration of head angular velocity signals from the semicircular canals could be used to estimate the change in angular head orientation relative to gravity. For example, the inertial component that is caused by head translation (vectorf) during a combined sinusoidal roll tilt plus translational motion could be extracted from the resultant otolith signal (vector α) by estimating the roll motion via integration of the roll velocity signal [vector ω = (ωx, 0, 0)], oriented along the head roll axis). Thus: Equation 3with describing roll tilt (re: gravity) as a function of time. In a more general case integration of 3-D angular velocity is more complex (e.g., Hess and Angelaki, 1997).
Second, a similar computational scheme utilizes angular velocity information from the semicircular canals (vector ω), as well as static and dynamic linear acceleration information from otolith afferents (vectors α and α˙ =dα/dt). Based on the fact that the resultant linear acceleration is equal to the vectorial sum of translational and gravitational components, i.e., α= f +g, and on the relationshipdg/dt = g˙ = ω × g (where × denotes the vector cross-product), which describes the rate of change of gravity, the translational component of acceleration (f) can be easily computed by solving the following differential equation (Viéville and Faugeras, 1990; Hess and Angelaki, 1997): Equation 4Despite its apparent complexity, Equation 4 could be easily implemented in the CNS through signal convergence between angular velocity (ω, from semicircular canal afferents), as well as static and dynamic linear acceleration (α and α˙, extracted from otolith afferents). The simplest neural network that could implement Equation 4 has been illustrated in Figure11 and requires a minimum of four distinct “vector” neurons. The first two perform multiplicative interaction of their inputs, and the third is assumed to linearly summate its inputs. The fourth neuron functions as a neural integrator. Such computational steps have been often proposed to occur within single neurons or assemblies of neurons (Torre and Poggio, 1978; Koch et al., 1983; Shen, 1989). Furthermore, head angular velocity signals (ω), as well as both linear acceleration (α) and its time derivative (α˙) signals have been shown to coexist in single vestibular brainstem neurons (Angelaki et al., 1993).
These computational schemes and the conclusions reached based on the results of this study are only pertinent to frequencies higher than 0.1 Hz in which semicircular canal afferents can provide veridical information about head angular velocity. Below ∼0.05–0.1 Hz, however, semicircular canal signals are no longer accurate detectors of head velocity. Several solutions and models have been proposed to account for low-frequency tilt–translational discrimination (e.g.,Glasauer and Merfeld, 1997) and remain to be further tested experimentally.
Detection of inertial motion: a fundamental sensorimotor task
Living and moving in a gravitational field places particular computational demands on inertial motion estimation. Although the peripheral sensory transduction of motion is dictated and bound by the laws of physics, the brain can use multisensory information to interpret sensory afferent signals and compute inertial motion. Specifically, the issue of inertial navigation and movement control has been long recognized as a major computational task for both biological and man-made inertial guidance systems (Fernandez and Macomber, 1962;Barlow, 1964; Beritoff, 1965; Mayne, 1969a,b). The vestibular labyrinths, like inertial guidance systems, are equipped with a set of 3-D linear accelerometers (otolith organs) and a set of 3-D angular accelerometers with built-in integrators that accurately detect head angular velocity in a wide frequency range (semicircular canals). The challenging computational task arises when these two independent sets of signals get combined to compute motion in space. Accurate separation of the resultant acceleration (α) into the translational and gravitational components (f and g, respectively) comprises only one, but perhaps the most important, computational demand (Fig. 12). Inertial control of movement requires that, in addition, absolute angular motion in space be computed. Because primary semicircular canal afferents only code for a relative, head-fixed velocity vector (ω), estimation of inertial velocity (ωs) requires a second processing stage that uses the gravitational estimate (g) to transform primary semicircular canal signals into space-referenced angular motion estimates (Fig. 12). Indeed, inertial velocity has been shown to be computed within the central vestibular system (Angelaki and Hess, 1994, 1995; Angelaki et al., 1995; Hess and Angelaki, 1997).
Appendix
Assuming a combined tilt–translation motion in which the roll oscillation amplitude is described as θ(t) = θo · sin(ωt), and the translational acceleration during linear motion is described asƒtr = ƒo · sin(ωt + γ) where γ is the relative phase between the two stimuli, the components of the gravitational and translation acceleration vectors in space- and head-fixed coordinates (Fig.13) are as follows (in G units, G = 9.81 m/sec2):
Gravity vector g:
in space-fixed coordinates:
gx = 0
gy = 0
gz = −1
in head-fixed coordinates (tilted by the angle θ relative to space):
gx = 0
gy = −sin(θ)
gz = −cos(θ)
Translational acceleration f:
in space-fixed coordinates:
fx = 0
fy = fosin(ωt + γ)
fz = 0
in head-fixed coordinates:
fx = 0
fy = fosin(ωt + γ)cos(θ)
fz = −fosin(ωt + γ)sin(θ)
Acceleration a (in head-fixed coordinates):
ax = fx +gx = 0
ay = fy +gy = fosin(ωt + γ)cos(θ) − sin(θ) (resultant IA acceleration)
az = fz +gz = − fo(ωt + γ)sin(θ) − cos(θ)
Condition for cancellation of IA acceleration:
ay = 0 = fosin(ωt + γ)cos(θ) − sin(θ)
Thus,
tan(θ) = tan (θo sin(ωt)) =fo sin(ωt + γ)
approximation for small θo: tan(θo) ≅ θo ≅ fo
Footnotes
This work was supported by National Institutes of Health Grant EY10851, Air Force Office of Scientific Research Grant F49620, and Swiss National Science Foundation Grant 31-47287.96.
Correspondence should be addressed to Dr. Dora Angelaki, Department of Surgery (Otolaryngology), University of Mississippi Medical Center, 2500 North State Street, Jackson, MS 39216-4505.