Skip to main content

Main menu

  • HOME
  • CONTENT
    • Early Release
    • Featured
    • Current Issue
    • Issue Archive
    • Collections
    • Podcast
  • ALERTS
  • FOR AUTHORS
    • Information for Authors
    • Fees
    • Journal Clubs
    • eLetters
    • Submit
    • Special Collections
  • EDITORIAL BOARD
    • Editorial Board
    • ECR Advisory Board
    • Journal Staff
  • ABOUT
    • Overview
    • Advertise
    • For the Media
    • Rights and Permissions
    • Privacy Policy
    • Feedback
    • Accessibility
  • SUBSCRIBE

User menu

  • Log out
  • Log in
  • My Cart

Search

  • Advanced search
Journal of Neuroscience
  • Log out
  • Log in
  • My Cart
Journal of Neuroscience

Advanced Search

Submit a Manuscript
  • HOME
  • CONTENT
    • Early Release
    • Featured
    • Current Issue
    • Issue Archive
    • Collections
    • Podcast
  • ALERTS
  • FOR AUTHORS
    • Information for Authors
    • Fees
    • Journal Clubs
    • eLetters
    • Submit
    • Special Collections
  • EDITORIAL BOARD
    • Editorial Board
    • ECR Advisory Board
    • Journal Staff
  • ABOUT
    • Overview
    • Advertise
    • For the Media
    • Rights and Permissions
    • Privacy Policy
    • Feedback
    • Accessibility
  • SUBSCRIBE
PreviousNext
Cover ArticleToolbox

Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex

Ryan C. Kelly, Matthew A. Smith, Jason M. Samonds, Adam Kohn, A. B. Bonds, J. Anthony Movshon and Tai Sing Lee
Journal of Neuroscience 10 January 2007, 27 (2) 261-264; https://doi.org/10.1523/JNEUROSCI.4906-06.2007
Ryan C. Kelly
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Matthew A. Smith
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Jason M. Samonds
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Adam Kohn
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
A. B. Bonds
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
J. Anthony Movshon
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
Tai Sing Lee
  • Find this author on Google Scholar
  • Find this author on PubMed
  • Search for this author on this site
  • Article
  • Figures & Data
  • Info & Metrics
  • eLetters
  • PDF
Loading

Advances in microelectrode neural recording systems have made it possible to record extracellular activity from a large number of neurons simultaneously. A substantial body of work is associated with traditional single-electrode extracellular recording, and the robustness of the recording method has been proven experimentally. However, the recordings are limited to a small number of cells at a time, so much of the work has relied on compiling population statistics across many recording sessions. Multielectrode recording systems theoretically have some major advantages over this paradigm. They increase the yield of neurons per recording session, and analysis of pairwise correlation benefits greatly from simultaneously recording from a large number of neurons (the number of pairs is proportional to the square of the number of cells). The larger population also provides the possibility of examining higher-order (non-pairwise) interactions among neurons (Schneidman et al., 2006; Shlens et al., 2006). Finally, multielectrode systems have been developed that may be implanted and used for several months, which permits the study of learning in cell populations. Here we assess this experimental approach for anesthetized acute preparations and compare the quality of recordings to those provided by the traditional single-electrode method.

Here we focus on a specific microelectrode device, the Cyberkinetics “Utah” Array (Cyberkinetics Neurotechnology Systems, Foxborough, MA) (Fig. 1A). This device is a 10 × 10 grid of silicon microelectrodes (1 mm in length) spaced 400 μm apart, covering 12.96 mm2. We analyzed recordings from single electrodes and the Utah array in macaques and cats. Previous reports on the quality (Nordhausen et al., 1996) and long-term stability (Suner et al., 2005) of array recordings have not made a quantitative, direct comparison with established single-electrode recordings. In light of the increasing popularity of the array, we addressed this uncertainty by comparing waveforms recorded with the array to waveforms recorded with accepted single-electrode techniques. We found that the array yields good recordings on a large number of electrodes, with qualities comparable to those from single-electrode recordings. On average, the recording quality is somewhat lower than that of single electrodes but, nonetheless, is sufficient for assessing tuning properties such as the spatiotemporal receptive field (STRF) and orientation tuning.

Figure 1.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1.

Cyberkinetics microelectrode array and example waveforms. A, The array, closeup, and perspective with a penny. B, Examples of sorted waveforms and SNRs from three representative channels and one channel of noise.

Recording methods

To assess the quality of microelectrode array recordings relative to standard single-electrode techniques, we analyzed waveforms from single-electrode and microelectrode array recordings from anesthetized, paralyzed macaque monkeys (Macaca fascicularis) and cats (Felis domesticus). Anesthesia was maintained with sufentanil and propofol with nitrous oxide, respectively. Monkeys were paralyzed with vecuronium bromide, and cats were paralyzed with pancuronium bromide. The impedance of microelectrodes in the array ranged from 200 to 800 kΩ with an average of 400 kΩ. For the macaque single-electrode recordings, we used quartz–platinum/tungsten microelectrodes (1.2–3 MΩ) in a seven-channel Eckhorn microdrive (Thomas Recording, Giessen, Germany). For the cat single-electrode recordings, we used tungsten in glass microelectrodes (0.5–2 MΩ) made locally (Levick, 1972), in a Burleigh Inchworm microdrive (Burleigh Instruments, Victor, NY), driven by piezoelectric elements. All measures of impedance were made with a 1 kHz sinusoidal current. Specific procedures for each of the following recording preparations have been reported previously: cat single electrode (Snider et al., 1998), cat array (Samonds et al., 2006), and monkey single electrode (Cavanaugh et al., 2002).

We used the following method to isolate waveforms generated by individual cells. For each electrode, waveform segments that exceeded a threshold (periodically adjusted using a multiple of the rms noise on each channel) were stored and sorted off-line with principal components analysis by waveform shape (Shoham et al., 2003). After this preliminary sort, we refined the output by hand with off-line time–amplitude window discrimination software for each electrode. All waveforms were sorted in this manner except for the V2 macaque data, which were sorted on-line with a dual time–amplitude window discriminator.

Signal-to-noise ratio

Using this procedure, we analyzed 58 V1 cells from single electrodes in cats, 38 V2 cells from single electrodes in macaques, 269 V1 cells from three microelectrode arrays in cats, and 301 V1 cells from three microelectrode arrays in macaques. In Figure 1B, we show waveforms from three neurons recorded with the microelectrode array in macaque V1. These examples span the quality range we typically observed with arrays. Given these isolated single units, we computed signal-to-noise ratios (SNRs) for collections of waveforms recorded in 1 h periods for each of the four preparations. The SNR is computed as the ratio of the amplitude of the average waveform to the SD of waveform noise (Nordhausen et al., 1996; Suner et al., 2005). That is, if each of k waveforms has n samples, then the collection of waveforms is as follows: Embedded Image with the mean waveform denoted as W̄. The matrix of noise values (deviations from the mean) is thus as follows: Embedded Image where the SDε is the SD of the collection of all entries in ε. The SNR is now as follows: Embedded Image

Response properties

Waveforms collected with the microelectrode arrays were similar in shape to waveforms collected using single electrodes, and neuronal response properties were similar as well. To demonstrate this point, we analyzed neural responses to a variety of stimuli collected with macaque V1 array implants. Orientation tuning curves were derived from responses to drifting sinusoidal gratings (Fig. 2A). Most isolated cells showed clear orientation preference, and orderly shifts in orientation preference could be seen across the electrode positions in the array. In addition, we computed STRFs for cells responding to white-noise stimuli using spike-triggered averaging (Fig. 2B). STRFs were found for cells when a contiguous 30 pixel area of the spike-triggered average exceeded 3 SDs of the noise average. Of the cells isolated with this array, 60–65% revealed STRFs. Overall, we found that tuning properties were similar to those reported previously for orientation tuning (Hubel and Wiesel, 1968; Ringach et al., 2002) and STRFs (Jones and Palmer, 1987).

Figure 2.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2.

Response properties. A, Orientation tuning curves for 16 example neurons in response to a sinusoidal grating drifting in 12 different directions. The grating was fixed at a spatial frequency of 1.3 cycles/degree, temporal frequency of 6.25 Hz, size of 8°, and duration of 1.28 s with 1.5 s between stimuli. B, STRFs generated with reverse correlation of responses to white-noise stimuli for the same 16 neurons.

We compared the distribution of SNRs across the different animals and methodologies (Fig. 3). On a population level, SNR values for the arrays tended to be somewhat lower than those from single-electrode recordings in both macaques and cats (see Fig. 3 legend for statistics). One reason for this is that the electrode depth of the array is fixed after implantation and cannot be adjusted to better isolate a cell, as is typically done in single-electrode recordings. Another possibility is that our array recordings were confined mostly to layers 2–3 with the rest in layer 4 (Jermakowicz et al., 2006), whereas our single-electrode data included cells sampled throughout the cortical depth. A direct comparison of cells recorded in the same layer might have yielded slightly different results, although there is no reason to suspect it would systematically bias the SNR values in either direction. The average SNRs from cat recordings were somewhat higher than from macaque data. This may be attributable to a true difference between species or merely related to variations in recording setups. Despite the disparity in distribution means, the cells in the different conditions span the same SNR range. That is, cells with the lowest SNR from arrays were still within the distribution from accepted single-electrode recordings using an on-line dual time–amplitude window discriminator.

Figure 3.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 3.

SNRs in the four preparations. A, B, Macaque array SNR (A) tended to be lower than single-electrode SNR (B; two-sample Kolmogorov–Smirnov goodness-of-fit hypothesis test, p < 0.0001). C, D, Similarly, cat array SNR (C) was lower than single-electrode SNR (D; p = 0.046). Finally, there was a trend for recordings in cats to have higher SNRs than recordings in the macaques for single electrodes (p = 0.10) and arrays (p < 0.0001). All SNR values were computed from the waveforms over ∼1 h of recording time.

Stability of recordings

One advantage of the acute preparation is the ability to record for many hours consecutively. We addressed the stability of recording across a 29 h period from one of our macaque array implants. Our sorting method was applied across the entire recording duration, and thus the quality of recordings from individual cells was tracked over time. Figure 4shows the change in the SNR for all cells over the time period starting 2 h after array implantation. Most SNR values tend to remain relatively constant throughout recording, with a few fluctuating between high and low SNRs. One trend we observed was that cells had lower SNR values near implantation and improved over the course of recording (Pearson r = 0.27; p < 0.0001). Of 127 cells from this array, 88 (69%) had a significant (p < 0.05) increase in SNR, whereas only 2 cells showed a significant decrease in SNR. Evolution of the mean SNR over time is shown at the top of Figure 4.

Figure 4.
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 4.

Stability of SNR. Here we show the log (SNR) values for a continuous 29 h recording session from one array implant. The cells here are sorted in decreasing order by average SNR value across time. The plot above shows the average SNR across all cells for each hour (error bars are ±1 SEM).

Review of microelectrode array

Use of the Cyberkinetics microelectrode array has some considerations relative to single-electrode techniques. It is currently manufactured in two fixed electrode lengths (1 or 1.5 mm), and insertion depth is not adjustable after implantation. For our array recordings, we used a 1.0 mm array with a 0.6 mm pneumatic insertion (Rousche and Normann, 1992). This partial insertion resulted in electrode tips positioned mostly in superficial layers. An additional consideration is that the size and shape of the array prevents implantation in some locations accessible to single electrodes, such as within sulci. Also, because the array is flat and the cortical surface is curved, there is some chance that electrodes record from different layers. Finally, the implant procedure is somewhat more complicated than the preparation for single-electrode recordings (Rousche and Normann, 1992). However, we observed no significant damage or edema after implantation and even after removal of the array (potentially facilitated by partial insertion).

We found that the array produced SNRs similar to those of single-electrode recordings, both when the same spike-sorting method was used and when spikes were sorted with standard on-line techniques. Although the ranges of SNR distributions were similar, single-electrode recordings had higher SNR values on average. This may be resulting from the higher impedances of single electrodes but is also likely to be strongly influenced by the fixed electrode depth of the array. The stability of recording may be influenced by the fact that single-electrode setups are mounted externally, whereas the array is allowed to float with the motions of the cortex resulting from heartbeat and respiration. Our recordings from arrays had orientation tuning and STRFs in most cells. These cells were relatively stable throughout the day after implantation, with no signs of degradation after 30 h (indeed, the signals tended to improve over time). A typical array implantation yielded 100 distinct candidate waveforms split approximately evenly between single-unit and multiunit activity. Aside from increasing the amount of single-unit data, arrays produce a high yield of neuronal pairs, providing a viable foundation for the study of higher-order correlation properties.

Footnotes

  • This work was supported by a National Science Foundation (NSF) Integrative Graduate Education and Research Traineeship to R.C.K. (DGE-0549352), National Eye Institute (NEI) National Research Service Award fellowship to M.A.S. (EY015958), National Institute of Mental Health Grant MH 64445 and NSF Grant CISE IIS 0413211 to T.S.L., and NEI grants to A.B.B. (EY014680) and J.A.M. (EY02017). Single-electrode cat data were collected by Ross Snider, cat array data were collected in part by Zhiyi Zhou and Melanie Bernard, and macaque single-electrode data were collected in part by Yasmine El-Shamayleh. We thank David Linn for technical assistance.

  • Editor's Note: Toolboxes are intended to briefly highlight a new method or a resource of general use in neuroscience or to critically analyze existing approaches or methods. For more information, see www.jneurosci.org/misc/itoa.shtml.

  • Correspondence should be addressed to Ryan C. Kelly, Center for the Neural Basis of Cognition, Carnegie Mellon University, 4400 Fifth Avenue, Mellon Institute, Room 115, Pittsburgh, PA 15213. rkelly{at}cs.cmu.edu

References

  1. ↵
    1. Cavanaugh JR,
    2. Bair W,
    3. Movshon JA
    (2002) Nature and interaction of signals from the receptive field center and surround in macaque V1 neurons. J Neurophysiol 88:2530–2546.
    OpenUrlAbstract/FREE Full Text
  2. ↵
    1. Hubel D,
    2. Wiesel T
    (1968) Receptive fields and functional architecture of monkey striate cortex. J Physiol (Lond) 195:215–243.
    OpenUrlAbstract/FREE Full Text
  3. ↵
    1. Jermakowicz WJ,
    2. Chen X,
    3. Khaytin I,
    4. Zhou Z,
    5. Bernard M,
    6. Bonds AB,
    7. Casagrande VA
    (2006) Does spike synchrony provide a better code of stimulus angle than average firing rate? J Vis 6:66a.
    OpenUrl
  4. ↵
    1. Jones JP,
    2. Palmer LA
    (1987) The two-dimensional spatial structure of simple receptive fields in cat striate cortex. J Neurophysiol 58:1187–1211.
    OpenUrlAbstract/FREE Full Text
  5. ↵
    1. Levick W
    (1972) Another tungsten microelectrode. Med Biol Eng 10:510–515.
    OpenUrlCrossRefPubMed
  6. ↵
    1. Nordhausen CT,
    2. Maynard EM,
    3. Normann RA
    (1996) Single unit recording capabilities of a 100 microelectrode array. Brain Res 726:129–140.
    OpenUrlCrossRefPubMed
  7. ↵
    1. Ringach DL,
    2. Shapley RM,
    3. Hawken MJ
    (2002) Orientation selectivity in macaque V1: diversity and laminar dependence. J Neurosci 22:5639–5651.
    OpenUrlAbstract/FREE Full Text
  8. ↵
    1. Rousche PJ,
    2. Normann RA
    (1992) A method for pneumatically inserting an array of penetrating electrodes into cortical tissue. Ann Biomed Eng 20:413–422.
    OpenUrlCrossRefPubMed
  9. ↵
    1. Samonds JM,
    2. Zhou Z,
    3. Bernard MR,
    4. Bonds AB
    (2006) Synchronous activity in cat visual cortex encodes collinear and cocircular contours. J Neurophysiol 95:2602–2616.
    OpenUrlAbstract/FREE Full Text
  10. ↵
    1. Schneidman E,
    2. Berry MJ,
    3. Segev R,
    4. Bialek W
    (2006) Weak pairwise correlations imply strongly correlated network states in a neural population. Nature 440:1007–1012.
    OpenUrlCrossRefPubMed
  11. ↵
    1. Shlens J,
    2. Field GD,
    3. Gauthier JL,
    4. Grivich MI,
    5. Petrusca D,
    6. Sher A,
    7. Litke AM,
    8. Chichilnisky EJ
    (2006) The structure of multi-neuron firing patterns in primate retina. J Neurosci 26:8254–8266.
    OpenUrlAbstract/FREE Full Text
  12. ↵
    1. Shoham S,
    2. Fellows MR,
    3. Normann RA
    (2003) Robust, automatic spike sorting using mixtures of multivariate t-distributions. J Neurosci Methods 127:111–122.
    OpenUrlCrossRefPubMed
  13. ↵
    1. Snider RK,
    2. Kabara JF,
    3. Roig BR,
    4. Bonds AB
    (1998) Burst firing and modulation of functional connectivity in cat striate cortex. J Neurophysiol 80:730–744.
    OpenUrlAbstract/FREE Full Text
  14. ↵
    1. Suner S,
    2. Fellows MR,
    3. Vargas-Irwin C,
    4. Nakata GK,
    5. Donoghue JP
    (2005) Reliability of signals from a chronically implanted, silicon-based electrode array in non-human primate primary motor cortex. IEEE Trans Neural Syst Rehabil Eng 13:524–541.
    OpenUrlCrossRefPubMed
Back to top

In this issue

The Journal of Neuroscience: 27 (2)
Journal of Neuroscience
Vol. 27, Issue 2
10 Jan 2007
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by author
Email

Thank you for sharing this Journal of Neuroscience article.

NOTE: We request your email address only to inform the recipient that it was you who recommended this article, and that it is not junk mail. We do not retain these email addresses.

Enter multiple addresses on separate lines or separate them with commas.
Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex
(Your Name) has forwarded a page to you from Journal of Neuroscience
(Your Name) thought you would be interested in this article in Journal of Neuroscience.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Print
View Full Page PDF
Citation Tools
Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex
Ryan C. Kelly, Matthew A. Smith, Jason M. Samonds, Adam Kohn, A. B. Bonds, J. Anthony Movshon, Tai Sing Lee
Journal of Neuroscience 10 January 2007, 27 (2) 261-264; DOI: 10.1523/JNEUROSCI.4906-06.2007

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Respond to this article
Request Permissions
Share
Comparison of Recordings from Microelectrode Arrays and Single Electrodes in the Visual Cortex
Ryan C. Kelly, Matthew A. Smith, Jason M. Samonds, Adam Kohn, A. B. Bonds, J. Anthony Movshon, Tai Sing Lee
Journal of Neuroscience 10 January 2007, 27 (2) 261-264; DOI: 10.1523/JNEUROSCI.4906-06.2007
Twitter logo Facebook logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Footnotes
    • References
  • Figures & Data
  • Info & Metrics
  • eLetters
  • PDF

Responses to this article

Respond to this article

Jump to comment:

No eLetters have been published for this article.

Related Articles

Cited By...

More in this TOC Section

  • Monosynaptic Circuit Tracing with Glycoprotein-Deleted Rabies Viruses
  • Granger Causality Analysis in Neuroscience and Neuroimaging
  • Investigating Axonal Guidance with Microdevice-Based Approaches
Show more Toolbox
  • Home
  • Alerts
  • Follow SFN on BlueSky
  • Visit Society for Neuroscience on Facebook
  • Follow Society for Neuroscience on Twitter
  • Follow Society for Neuroscience on LinkedIn
  • Visit Society for Neuroscience on Youtube
  • Follow our RSS feeds

Content

  • Early Release
  • Current Issue
  • Issue Archive
  • Collections

Information

  • For Authors
  • For Advertisers
  • For the Media
  • For Subscribers

About

  • About the Journal
  • Editorial Board
  • Privacy Notice
  • Contact
  • Accessibility
(JNeurosci logo)
(SfN logo)

Copyright © 2025 by the Society for Neuroscience.
JNeurosci Online ISSN: 1529-2401

The ideas and opinions expressed in JNeurosci do not necessarily reflect those of SfN or the JNeurosci Editorial Board. Publication of an advertisement or other product mention in JNeurosci should not be construed as an endorsement of the manufacturer’s claims. SfN does not assume any responsibility for any injury and/or damage to persons or property arising from or related to any use of any material contained in JNeurosci.