Table 2.

Changes on the E–I ratio of the frequency, amplitude, and charge of spontaneous EPSCs and IPSCs in 3 versus 1 mm extracellular Ca2+

3 mm Ca2+1 mm Ca2+
Pyramidal cells
    Frequency0.71 ± 0.2313.76 ± 10.53*
    Amplitude0.91 ± 0.211.78 ± 0.31*
    Charge0.77 ± 0.252.48 ± 0.66*
    n66
Interneurons
    Frequency5.64 ± 4.0735.75 ± 17.09*
    Amplitude1.79 ± 0.592.53 ± 1.01
    Charge1.19 ± 0.481.71 ± 1.19
    n64
  • Experiments were performed with standard pipette solution (see Materials and methods), and events were detected at −60 mV.

  • *p < 0.05 for statistical comparisons between different calcium concentrations.